期刊文献+

非放射性甲基碘示踪法测量碘吸附器效率实验

Experimental exploration for measuring iodine adsorber efficiency by non-radioactive methyl iodine tracer
原文传递
导出
摘要 研究了碘吸附器效率测试过程中甲基碘在供料和洗脱阶段的吸附和脱附行为,为采用非放射性甲基碘进行效率测试取样时间的确定提供了依据。同时研究了采用非放射性碘甲烷和放射性碘甲烷对碘吸附器进行效率检测时的异同,分别考察了存在机械泄漏和浸渍剂部分损失两种条件下用不同示踪剂所测结果,并对存在的异同进行了理论分析。结果表明,当碘吸附器机械泄漏占主导时,两种试剂所测结果具有较好的一致性,且泄漏面积越大,一致性越好;当碘吸附器机械泄漏率可以忽略时,两种试剂测量结果存在较大偏差。 The adsorption and desorption behaviors of methyl iodine in the feeding and elution stages of iodine absorber efficiency test is studied,which provides a basis for determining the sampling time in efficiency test with non-radioactive methyl iodine.The differences and similarities in using non-radioactive methane iodide and radioactive methane iodide to test the efficiency of iodine sorbent are studied.The results from using different tracers under mechanical leakage and partial loss of impregnating agent are investigated respectively,and the differences and similarities are analyzed through theoretical analysis.It is shown that the results by two reagents have a good consistency when the mechanical leakage of iodine adsorber is dominant.The greater the leakage area,the better the consistency.When the mechanical leakage rate of iodine sorbent can be ignored,there is a large deviation in the measurement results by two reagents.
作者 俞杰 张雪平 徐琳银 李昕 陈欣 李永国 张诚 YU Jie;ZHANG Xue-ping;XU Lin-yin;LI Xin;CHEN Xin;LI Yong-guo;ZHANG Cheng(Institute of Environmental Engineering Technology,China Institute for Radiation Protection,Taiyuan 030006,China;CNNC Nuclear Power Operation Management Co.,Ltd.,Jiaxing 314300,China)
出处 《现代化工》 CAS CSCD 北大核心 2022年第S02期399-402,共4页 Modern Chemical Industry
基金 国家重点研发计划“放射性碘气溶胶净化的离子瀑技术应用研究”(2017YFE0115100)
关键词 碘吸附器 效率 非放射性 甲基碘 iodine adsorber efficiency non-radioactive methyl iodine
  • 相关文献

参考文献4

二级参考文献13

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部