期刊文献+

小母线电容永磁同步电机调速系统的改进型功率控制策略

An improved power control strategy for permanent magnet synchronous motor drive system with small DC-link capacitor
下载PDF
导出
摘要 永磁同步电机的小母线电容调速系统具有成本低、可靠性高等优点,但其直流母线电压波动的负面效果将极大降低调速系统性能。为了提高调速系统的输入功率因数,减少输入电流谐波含量,研究一种应用于小母线电容调速系统的改进型功率控制策略。该策略以功率反馈控制变量代替传统的速度反馈控制变量,并采用改进型PID调节器降低控制误差,以及动态积分饱和限制策略抑制调节器的积分饱和现象,实现对电机功率变量的精确控制。最后,在仿真平台上测试应用改进型功率控制策略的小母线电容电机调速系统的控制效果,证明了该策略能够有效地提高小母线电容电机调速系统的输入功率因数,并抑制控制过程中PID调节器的积分饱和现象。 Permanent magnet synchronous motor drive system with small DC-link capacitor has advantages such as low cost and good reliability.However,DC-link voltage pulsation,a side effect of the system,reduces the control system’s performance.To improve the system’s input power factor and reduce harmonics in input currents,an improved power control strategy is put forward in this paper.Differing from traditional speed feedback control method,this strategy uses power as the input control variable.An improved PID controller is selected to reduce control error.Additionally,an active suppression strategy is applied in the system to suppress the integral saturation and achieve the goal of precise control effect.This improved motor drive system was tested in simulation platform and its control performance proved that the control system improved by power control strategy can maintain a high input power factor and suppress integral saturation effectively.
作者 韩一博 宋昕昱 HAN Yibo;SONG Xinyu(Gree Electric Appliances,INC.of Zhuhai,Zhuhai 519070)
出处 《家电科技》 2020年第S01期106-110,共5页 Journal of Appliance Science & Technology
关键词 永磁同步电机 小母线电容 输入功率因数 积分饱和现象 Permanent magnet synchronous motor Small DC-link capacitor Input power factor Integral saturation
  • 相关文献

参考文献6

二级参考文献36

  • 1王萍,孙雨耕,许会军,张珂,宋良瑜.逆变器直流侧谐波分析与有源补偿[J].中国电机工程学报,2005,25(14):52-56. 被引量:38
  • 2Inazuma K,Utsugi H,Ohishi K, et al.High-Power-Factor Single-PhaseDiode Rectifier Driven by Repetitively Controlled IPM Motor. IEEETransactions on Industrial Electronics . 2013
  • 3H.Yoo,Seung-Ki Sul,Hoyong Jang,Youngho Hong.Design of a Variable Speed Compressor Drive System for Air-Conditioner without Electrolytic Capacitor. Industry Applications Conference . 2007
  • 4H.Lamsahel,P.Mutschler.Permanent magnet drives with reduce d dc-link capacitor for home appliances. IEEE IECON’’09 . 2009
  • 5Utsugi H,Ohishi K,Haga H.Reduction in current harmonics of electrolytic capacitor-less diode rectifier using inverter-controlled IPM motor. IEEE Industrial Electronics Society . 2012
  • 6IsaoTakahashi,HitoshiHaga.??Power factor improvement of single‐phase diode rectifier circuit by field‐weakening of inverter‐driven IPM motor(J)Elect. Eng. Jpn. . 2005 (2)
  • 7Euzeli Cipriano dos Santos,Cursino Brandao Jacobina,Gregory Arthur de Almeida Carlos.Component Minimized AC-DC-AC Single-Phase to Three-Phase Four-Wire Converters. IEEE Transactions on Industrial Electronics . 2011
  • 8A.M.Imam,T.G.Habetler,R.G.Harley,D.M.Divan.Condition Monitoring of Electrolytic Capacitor in Power Electronic Circuits using Adaptive Filter Modeling. Power Electronics Technology . 2005
  • 9Markus A. Vogelsberger,Thomas Wiesinger,Hans Ertl.Life-Cycle Monitoring and Voltage-Managing Unit for DC-Link Electrolytic Capacitors in PWM Converters. IEEE Transactions on Power Electronics . 2011
  • 10Hyun-Sam Jung,Seung-Jun Chee,Seung-Ki Sul,Young-Jae Park,Hyun-Soo Park,Woo-Kyu Kim.Control of Three-Phase Inverter for AC Motor Drive With Small DC-Link Capacitor Fed by Single-Phase AC Source. IEEE Transactions on Industrial Electronics . 2014