摘要
大量高层办公楼类型建筑采用框架-核心筒结构,这种类型建筑除核心筒外,外围柱网尺寸往往较大,如何选择一个合理的楼盖结构方案对工程总造价影响巨大。拟结合某工程实例,对这种类型建筑楼盖采用各种结构布置方案进行了较为深入探讨,抛砖引玉,供同类工程参考。
How to choose a rational floor to build the structure with great influence on total fabrication cost of the project,A high-story office building often adopts frame-corewall structure,the peripheral column network size of this kind of building often relatively large.Combining a project embodiment,it is discussed that the layout schemes of the floor of this sort of building,which may be a reference for similar projects.
出处
《工业建筑》
CSCD
北大核心
2007年第z1期340-344,共5页
Industrial Construction
关键词
框架-核心筒
空心楼盖
预应力楼板
预应力框架梁
frame-corewall structure cast-in-situ hollow concrete floor prestressed floor prestressed beam