期刊文献+

基于图像非线性配准的MRI几何失真校正 被引量:3

Correction of Geometric Distortion in MRI Based on Non-linear Image Registration
下载PDF
导出
摘要 采用图像非线性配准的方法,对MRI存在的几何失真进行校正,先选取与MRI具有共同解剖结构且基本无几何失真的CT图像,作为配准校正的目标基准图像,将MRI与CT图像进行刚体配准,然后采用人工选点的方法,寻找CT图像和MRI中的对应标记点集,用改进的弹体样条函数进行全局非线性配准。结果表明:弹体样条变换具有较强的非线性校正能力,较好地实现了二维MRI的几何失真校正。我们采用的变换模型有效可行,并可用于三维失真图像的校正。 To correct the geometric distortion by means of non-linear image registration.CT image was selected as reference image,which has the same anatomical structure as MRI but almost has no geometric distortion.MRI was matched with CT image by rigid body registration and a manual approach was used to seek corresponding points between CT image and MRI.Then,the improved elastic body spline was adopted to make global non-linear registration with these corresponding points extracted.Results showed that the elastic body spline transformation possessed strong ability to correct non-linear distortion and a desirable 2-D corrected MRI was got.Experiments show that it is an effective correction approach and can be conveniently used to the correction of 3-D distorted MRI.
作者 於锋 於文雪
出处 《生物医学工程研究》 2006年第4期239-242,共4页 Journal Of Biomedical Engineering Research
关键词 几何失真 刚体配准 弹体样条 非线性配准 校正 Geometric distortion Rigid body registration Elastic body spline Non-linear registration Correction
  • 相关文献

参考文献14

  • 1付杰,胡超苏,何少琴.MRI模拟研究进展[J].中华放射肿瘤学杂志,2005,14(4):310-313. 被引量:5
  • 2[2]Khoo V S,Dearnaley D P,Finnigan D J,et al.Magnetic resonance imaging (MRI):considerations and applications in radiotherapy treatment planning[J].Radiotherapy and Oncology,1997,42:1-15.
  • 3[3]Fransson A,Andreo P,Potter R.Aspects of MR image distortions in radiotherapy treatment planning[J].Strahlentherapie Onkol,2001,2:59-73.
  • 4[4]Deming Wang,Doddrell D M,Cowin G.A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging[J].Magnetic Resonance Imaging,2004,22:529-542.
  • 5[5]Chang H,Fitzpatrick JM.A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities[J].IEEE Trans Med Imag,1992,11:319-329.
  • 6[6]Van den Elsen P A,Viergever M A.Marker guided multimodality matching of the brain[J].European Radiology,1994,4(1):45-51.
  • 7[7]Van Herk,M.,Kooy,H.M.Automatic three-dimension correlation of CT-CT,CT-MRI,CT-SPECT using chamfer matching[J].MedPhys,1994,21:1163-1178.
  • 8[8]Breeuwer M,Holden M,Zylka W.Detection and correction of geometric distortion in 3D MR images[J].Medical Imaging:image processing,2001,4322:1110-1120.
  • 9[9]Bookstein FJ.Principle warps:thin-plate splines and the decomposition of deformations[J].IEEE Trans Pattern Analysis and Machine Intelligence,1989,11(6):567-585.
  • 10[10]Davis MH,Khotanzad A,Flaming DP,et al.A physics-based coordinate transformation for 3-D image matching[J].IEEE Transactions on Medical Imaging,1997,16 (3):317-328.

二级参考文献35

  • 1杨广夫,勒宝善.磁共振诊断学.西安:陕西科学技术出版社,1998.37-37.
  • 2Ogino T, Nawano S, Shimizu w, et al. CineMRI in radiotherapy treatment planning of brain tumor. Radiat Med, 1993,11:201-205.
  • 3van den Elsen PA, Pol E,Viergever MA. Medical image matching-A review with classification. IEEE Trans. Med Biomed Eng, 1993, 12: 26-39.
  • 4Sarkar A, Santiago RJ, Smith R, et al. Comparison of manual vs. automated multimodality (CT-MRI) image registration for brain tumors. Med Dosim,2005,30:20-24.
  • 5Clarke LP, Velthuizen RP, Camacho MA, et al. MRI segmentation:methods and appilication. Magnetic Resonance Imaging, 1995,13: 343-368.
  • 6Bondiau PY, Malandain G, Chanalet S, et al. Atlas-based automatic segmentation of MR images: validation study on the brainstem in radiotherapy context. Int J Radiat Oncol Biol Phys,2005,61:289-298.
  • 7Chen L, Li J, Mah D, et al. Monte carlo verification of mr-based treatment planning for intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys, 2002,54 Suppl 1: 329.
  • 8Just M, Rosler HP, Higer HP, et al. MRI-assisted radiation therapy planning of brain tumors: clinical experiences in 17 patients. Ma~etic Resonance Imaging, 1991,9:173-177.
  • 9Heester MA, Wijrdeman HK, Strukmans H, et al. Brain tumor delineation based on Ctand mrIMAGING. Strahlenther Onkol, 1993,169:729-733.
  • 10Potter R, Heil B, Schneider L, et al. Sagittal and coronal planes from MRI for treatment planning in tumors of brain, head and neck: MRI assisted simulation. Radiother Oncol,1992, 23:127-130.