摘要
采用处理量为0.08m3/h的一体式膜生物反应器处理城市生活污水。实验结果表明:0.073MPa的操作压力下,膜通量能维持在0.02m3/(m2·h)这一较高的水平,且此时的最佳曝气量为150L/min。实验出水水质稳定且优于生活杂用水回用标准,可直接回用。
In the paper,an experiment is made to investigate the mechanism of urban domestic wastewater treatment by utilizing the submerged membrane bioreactor with the processing rate of (0.08 m^3/h.) The experiment results show that the optimal transmembrane pressure is 0.073 Mpa under which the membrane flux can be maintained at the higher level of 0.02 m^3/(m^2·h) and the optimal aeration rate is found to be 150 L/min. Under the above conditions,the effluent quality is stable and better than the water quality standard for reuse issued by the Ministry of Construction of China.
出处
《合肥工业大学学报(自然科学版)》
CAS
CSCD
2004年第10期1284-1287,共4页
Journal of Hefei University of Technology:Natural Science
关键词
膜生物反应器
膜通量
操作压力
曝气量
membrane bioreactor
membrane flux
transmembrane pressure
aeration rate