采用错流式生物滴滤反应器净化甲苯废气 被引量:4

Removal of Toluene Waste Gas by a Cross-flow Trickling Biofilter
下载PDF
导出
摘要 为了解决生物滴滤塔有效降解空间低,压降高,易堵塞等问题,采用错流式生物滴滤反应器,以单一底物甲苯驯化的纯菌种恶臭假单胞菌为菌源接种,陶粒为填料,处理含甲苯废气.研究了反应器的挂膜启动、不同停留时间、不同体积负荷以及营养液温度对反应器甲苯处理能力的影响.反应器挂膜启动仅需要7d,挂膜成功后,停留时间为144、72、48和36s时,最大体积去除负荷为276.62g/(m^3·h),营养液最佳温度为28~34℃.结果表明,采用错流式生物滴滤反应器净化甲苯废气是一种可行有效的的工艺,设备结构和操作方式的改变提高了生物降解的有效空间,并可以有效调节反应器内的湿度,适于大气量挥发性有机废气的治理;停留时间的变化对反应器处理性能的影响较小,且可以迅速恢复;控制营养液温度可以调整反应器微生物生存的环境温度,从而提高反应器去除效率. In this paper,the cross-flow trickling biofilter was used to remove toluene from an artificial waste gas in order to resolve problems of the columned trickling biofilter,such as low effective zone,high pressure and easily clogging.The biofilter was inoculated with Pseudomonas Pudida and packed with biological ceramic pellets.The start-up process and the performance of the biofilter under different residence time and volumetric loading were studied.The effects of the temperature of nutrients on the removal c...
出处 《北京工业大学学报》 EI CAS CSCD 北大核心 2009年第2期246-251,共6页 Journal of Beijing University of Technology
基金 北京市自然科学基金资助项目(8052004) 北京工业大学青年基金资助项目(97005013200402).
关键词 错流 生物滴滤 甲苯 恶臭假单胞菌 cross-flow bio-trickling toluene Pseudomonas putida