摘要 目的应用CGMS进行血糖监测,了解血糖波动谱,据此调整患者饮食、运动及药物治疗,更快、更直观、更平稳降低血糖。方法用CGMS对34例DM患者进行连续3天的血糖监测,分析DM患者血糖特点,调整治疗方案。结果CGMS所测的血糖值与指端血糖值呈显著正相关(r=0.89,P<0.01),患者一天中血糖较高的时间段为早、午餐后2h,9:00~12:00是血糖高峰最集中(55.5%)的时间段,而51.5%的血糖低谷值出现在1:00~6:00。调整治疗方案后,血糖控制理想比例由63.9%上升至87%,低血糖发生率由8.6%降至1.4%。结论动态血糖监测能较好地评估血糖漂移,根据全天的血糖谱,制订整体的治疗方案,有助于更有效地控制血糖。
出处 《延安大学学报(医学科学版)》 2009年第2期18-19,共2页 Journal of Yan'an University:Medical Science Edition
  • 相关文献

参考文献5

  • 1[1]Marfella R,Nappe F,Ve Angelis L,et a.l Hemodynamic effects of acute hyperglycemia in type 2 diabetic patients[J].Diabetes Care,2000,23(5):658-660.
  • 2[2]Goldstein DE,Nuthun D,Little RR,et al.Test of glycemin indiabetes.Diabetes care 2004;27:1761-1773.
  • 3喻明,周健,项坤三,李鸣,李青,周逸常.动态监测新诊断2型糖尿病患者的血糖水平[J].中华糖尿病杂志(1006-6187),2005,13(2):102-104. 被引量:87
  • 4[4]Boyne M s,Silver D M,Kaplan J,et al.Timing of changes ininterstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor.Diabetes 2003;52:2790-2794.
  • 5黄晨,李榕,徐先桔,吴利平,高建苑,王晓明,薛富波.持续性血糖监测系统临床应用的可靠性研究[J].中国实用内科杂志,2006,26(1):37-38. 被引量:39

二级参考文献11

  • 1Gross TM, Bode BW, Einhorn D, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther,2000,2:49-56.
  • 2Mastrototaro J. The MiniMed continuous glucose monitoring system(CGMS). J Pediatr Endocriol Metab, 1999,12:751-758.
  • 3Bode BW, Gross TM, Thornton KR, et al. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin. Diabetes Res Clin Pract, 1999,46:183-190.
  • 4Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes, 2003, 52:2790-2794.
  • 5Steil GM, Rebrin K, Mastrototaro J, et al. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther,2003,5:27-31.
  • 6Kaufman FR, Carpenter S, Gibson LC, et al. A pilot study of the continuous glucose monitoring system. Diabetes Care, 2001,24:2030-2034.
  • 7Rohlfing CL, England JD, Wiedmeyer HM, et al. Defining the relationship between plasma glucose and HbA1c. Diabetes Care, 2002,25:275-278.
  • 8The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus. Report of the expert committee on the diagnosis and classification of diabetes mellitus [ J ]. Diabetes Care,1997, 20: 1183-1197.
  • 9Silverstein JH, Rosenbloom AL. New developments in type 1( insulin - dependent ) diabetes [ J ]. Clin Pediatr ( Phila ),2000, 39 (5): 257-266.
  • 10Mastrototaro J. The Minimend continuous glucose monitoring system (CGMS) [J]. J Pediatr Endocr Metab, 1999, 12:751 -758.

共引文献116

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部