摘要
主要介绍了利用DCS系统的热电偶模板,处理焦炉蓄热室顶部光电测温信号的思路和过程,为光电测温的应用提供了一种方法。
The article mainly introduces the meditation and procedure of dealing with the signal which was generated by the photoelectric thermometer fixed in the top of the regenerator of coke oven,the signal was received by the thermocouple input module in DCS.It offers a method to apply the photoelectric thermometer.
出处
《山东化工》
CAS
2007年第8期40-42,共3页
Shandong Chemical Industry
关键词
光电测温
焦炉
蓄热室
热电偶
函数
photoelectric thermometer
coke oven
refenerator
thermocouple
funtion