摘要
The purpose of this study was to develop a protein chip technique based on receptor binding assays to measure bioavailable serum sex hormone levels (BSSHL). 224 aging healthy Chinese were investigated to get the referenced values of BSSHL for the first time. In the assays recombined sex hormone receptor proteins were jointed to polysaccharide coated slides to make protein chip,; the dose-dependence curves of sex hormone on chip were prepared. The data showed that this method had good precision (CV>16%); accuracy (Bias>10%),; the sensitivity could reach 1 pmol/L. From the results, BSSHL of men; women declined with aging, but no significant differences were observed. The BSSHL of aging men were higher than those of women. The bioavailable serum;rogen level of men was 52–112 pmol/L, women’s was 3–70 pmol/L; the whole group was 41.9–81.4 pmol/L. The bioavailable serum estrogen level of men was 0.8–3.0 pmol/L, women’s was 1.2–2.5 pmol/L; the whole group was 0.6–2.64 pmol/L. Based on the assays, BSSHL measurement by protein chip can meet the needs of epidemiological studies in terms of speed, accuracy; sample volume required,; was helpful in quantitative assessment of aging people’s health.
The purpose of this study was to develop a protein chip technique based on receptor binding assays to measure bioavailable serum sex hormone levels (BSSHL). 224 aging healthy Chinese were investigated to get the referenced values of BSSHL for the first time. In the assays recombined sex hormone receptor proteins were jointed to polysaccharide coated slides to make protein chip, and the dose-dependence curves of sex hormone on chip were prepared. The data showed that this method had good precision (CV<16%) and accuracy (Bias<10%), and the sensitivity could reach 1 pmol/L. From the results, BSSHL of men and women declined with aging, but no significant differences were observed. The BSSHL of aging men were higher than those of women. The bioavailable serum androgen level of men was 52―112 pmol/L, women's was 3―70 pmol/L and the whole group was 41.9―81.4 pmol/L. The bioavailable serum estrogen level of men was 0.8―3.0 pmol/L, women's was 1.2―2.5 pmol/L and the whole group was 0.6―2.64 pmol/L. Based on the assays, BSSHL measurement by protein chip can meet the needs of epidemiological studies in terms of speed, accuracy and sample volume required, and was helpful in quantitative assessment of aging people's health.
作者
ZHOU Yong, CHANG Shuying, MENG Xiaoluo, YU Huafeng, WANG Luning, HE Jinggui, ZHANG Baohe, ZHANG Juntian, GENG Meiyu & DU Guanhua Institute of Marine Drugs and Food, Ocean University of China, Qingdao 266003, China
Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China
General Hospital of Air Force, PLA, Beijing 100036, China
304 Hospital of PLA, Beijing 100037, China
Beijing Tongren Hospital, Beijing 100730, China
General Hospital of PLA, Beijing 100853, China