期刊文献+

正确使用经颅多普勒超声减少其在临床的误用和滥用 被引量:6

Understanding the Transcranial Doppler Correctly for Avoiding Abuse in Clinical Application
下载PDF
导出
摘要   20世纪80年代末,能检测到颅内脑动脉血流的经颅多普勒超声(TCD)开始在我国临床应用.然而,十多年过去了,TCD是否确实有用及其可信程度依然被很多神经科医生所怀疑.……
作者 高山
出处 《中国卒中杂志》 2006年第3期165-168,共4页 Chinese Journal of Stroke
  • 相关文献

参考文献7

  • 1[1]Wong KS,Li H,Chan YL,et al.Use of transcranial Doppler ultrasound to predict outcome in patients with intracranial large artery occlusive disease[J].Stroke,2000,31:2641-2647.
  • 2[2]Gao S,Wong KS,Hansberg T,et al.Microembolic signal predicts recurrent cerebral ischemic events in acute stroke patients with middle cerebral artery stenosis[J].Stroke,2004,35(12):2832-2836.
  • 3[3]Huang YN,Gao S,Li SW,et al.Vascular lesions in Chinese patients with transient ischemic attacks[J].Neurology,1997,48(2):524-525.
  • 4[4]Markus HS,Thomson ND,Brown MM.Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease[J].Brain,1995,118:1005-1011.
  • 5[5]Wong KS,Gao S,Chan YL,et al.Mechanisms of acute cerebral infarctions in patients with middle cerebral artery stenosis:a diffusion-weighted imaging and microemboli monitoring study[J].Ann Neurol,2002,52(1):74-81.
  • 6[6]Markus H,Drost,Dirk W,et al.Detection of asymptomatic cerebral embolic signals with doppler ultrasound[J].Lancet,1994,1011-1012.
  • 7[7]Alexandrov AV,Molina CA,Grotta JC,et al.Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke[J].N Engl J Med,2004,351(21):2170-2178.

同被引文献55

  • 1何文.颅脑术中超声应用现状及进展[J].中华医学超声杂志(电子版),2006,3(4):200-203. 被引量:16
  • 2包静,李振东.颈动脉粥样硬化斑块及其危险因素与脑梗死的关系[J].陕西医学杂志,2008,37(12):1629-1631. 被引量:16
  • 3范常锋,黄一宁.2711例社区居民脑血管狭窄的流行病学调查[J].中华老年心脑血管病杂志,2007,9(1):36-38. 被引量:53
  • 4Sub DC, Lee SH, Kim KR, et al. Pattern of atherosclerotic carotid stenosis in Korean patients with stroke: different involvement of intracranial venus extracranial vessels[J].Am J Neuroradiol,2003,24(2):239-244.
  • 5Krejza J, Mariak Z, Lewko J. Standardization of flow velocities with respect to age and sex improves the accuracy of transcranial color Doppler sonography of middle cerebral artery[ J]. Am J Rocntgnol, 2003,181 (2) : 245-252.
  • 6Zouaui A, Sahel M, Marro B, et al. Three-dimensional computed tomographie angiography in detection of cerebral aneurysms in acute subarachnoid hemorrhage [ J ]. Neurosurgery, 1997,41 (2) : 125 - 130.
  • 7王拥军,经颅多普勒超声诊断手册[M].北京:人民卫生出版社,2009:35.
  • 8Krejza J, Mariak Z, Lewko J. Standardization of flow velocities with respect to age and sex improves the accuracy of transcranial color Doppler sonography of middle cerebral artery [ J ]. Am J Roentgnol, 2008,181(2) :245-252.
  • 9Zouaui A, Sahel M, Marro B, et al. Three-dimmasional computed tomographic angiography in detection of cerebral aneurysms in a- cute subarachnoid hemorrhage [ J ]. Neurosurgery, 1997, 41 ( 2 ) : 125-130.
  • 10Stein SC, Georgoff P, Meghan S, et al. 150 years of treating severe traumatic brain injury: a systematic review of progress in mortality[J]. J Neurotrauma, 2010, 27 (7) : 1343-1353. DOI: 10. 1089/neu. 2009. 1206.

引证文献6

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部