期刊文献+

锅炉炉顶吊杆负荷定量调整方法的探讨 被引量:1

Inquire into Regulating Method for Load of Hanger Rods on Boiler Roof
原文传递
导出
摘要 火电厂锅炉炉顶吊杆松弛及吊杆间负荷分配不合理是锅炉发生事故的隐患。通过江苏扬州发电有限公司 4号锅炉炉顶部分吊杆的实际测量和调整 ,对吊杆间负荷分配这一静不定问题进行了研究。根据锅炉炉顶吊杆分布的特点 ,研究设计了锅炉炉顶吊杆负荷监测系统。采用吊杆分区测量和调整 ,用松弛法确定基准值 ,实行吊杆负荷用仪器进行定量测量 ,根据测量结果 ,进行综合定量分析 ,再对吊杆实施精确调整 ,使吊杆受力趋于合理。 The loose of the hanger rods on boiler roof and unreasonable distribution of load among the hanger rods are hidden trouble to Boier accident.By measurement and adjustment of some hanger rods of No.4 boiler roof in Yangzhou Power Generation Limited Company,statically indeteminate load distribution among hanger rods is studied.According to distribution features of the hamger rods on boiler roof the design and study are carried out for load monitor system.The sectional measurement and adjustment for hanger rods are applied and the reference is determined by means of relaxation.The hanger rods load is measured quantitatively with instruments and comprehensive quantitative analysis is executed based on the measured results.Then fine adjustment for the hanger rods is carried out in order for the force is applied on the hanger rods mere reasonably.
出处 《电力建设》 北大核心 2002年第2期18-21,共4页 Electric Power Construction
关键词 锅炉 炉顶吊杆 负荷调整 boiler hanger rod on boiler roof load adjustment