摘要
对双曲线自然通风冷却塔的传热原理和配水系统进行了介绍,分析了冷却塔冬季运行结冰的部位和原因,结合生产实践详细阐述了防止结冰的各种有效措施。
The heat transmission principle and the water distributing system of the hyperbolic natural draft cooling tower were introduced.The freeze positions and freeze reason of the cooling tower in winter operation were analyzed.Combining with the production practice,various effective measures to prevent freeze were expounded.
出处
《电力技术》
2010年第8期22-24,共3页
Electric Power Standarization & Construction Cost Control Information
关键词
冷却水塔
结冰
处理
cooling tower
freeze
treatment