与600℃超超临界机组相比,700℃超超临界机组使锅炉蒸发段的吸热比例明显下降,其原因是炉侧烟气释放给水冷壁的纯辐射放热比例无法跟随700℃机组的锅内侧蒸汽吸热比例进行下调,锅内侧的过热度参数选择以及受热面的布置与现役600℃超超临界机组锅炉差异较大。因此,选择合适的过热度、布置蒸汽系统的受热面或设计新的过热器或再热器系统是700℃超超临界机组锅炉需要研究的重点课题。
Compared with 600 ℃ ultra-supercritical units,the heat absorption rate of evaporating section on boiler of the 700 ℃ unltra-supercritical unit decreases significantly.The proportion of pure radiant heat released by gas to the water wall can not be decreased by the heat absorption rate of steam in 700 ℃ unit boiler,so the superheating ratio selection and the heating surface arrangement had large difference with that of the present 600 ℃ ultra-supercritical unit boiler.Therefore,selecting a suitable superheating ratio,arranging heating surface of evaporating system and designing new superheater or reheater system are the key projects to investigate for the 700 ℃ ultra-supercritical unit boiler.
出处
《热力发电》
CAS
北大核心
2013年第1期59-62,共4页
Thermal Power Generation
关键词
700℃
超超临界机组
锅炉
蒸汽吸热比例
烟气放热比例
过热度
受热面
700 ℃
ultra-supercritical
boiler
heat absorption rate of steam
heat release rate of flue gas
superheating ratio
heating surface