期刊文献+

易于控制系统组态的低β值喉部取压喷嘴流量算法 被引量:1

Flow algorithm for low β ratio throat-tap nozzle which can control the system configuration easily
下载PDF
导出
摘要 以IAPWS-IF97工业用水和水蒸气公式为骨架,重新拟合出相对简单的水的密度及其动力粘度计算公式,该公式可满足水在全液态范围内的精度要求。本算法在简单计算公式的基础上,通过合理设定流出系数初值,避免大量迭代计算,仅2次计算即可得到准确结果,方便DCS等控制系统中的组态开发,并能将流量计算的误差控制在0.05%以内。 According to the IAPWS-IF97 industrial water equation and steam equation,the relatively simple calculation formula for water density and dynamic viscosity was fitted again,which can meet the precision requirement of water with entire liquid state.By setting the initial value of discharge coefficient reasonably,this algorithm avoids a lot of complex iterative process,and can obtain the correct results with only 2 times calculation.The new flow algorithm is convenient for configuration development of control system like the DCS,and can control the flow calculation error within 0.05%.
出处 《热力发电》 CAS 北大核心 2013年第10期-,共4页 Thermal Power Generation
关键词 低β值 喉部取压 喷嘴 水蒸气 low β ratio throat-tap nozzle water vapor configuration algorithm
  • 相关文献

参考文献5

  • 1ASME/ANSI.Measurement of fluid flowin pipes using orifice,nozzle and Ventri[].MFC-M.2004
  • 2Flow Measurement. ASME PTC19.5-2004 . 2004
  • 3The International Association for the Properties of Water and Steam.IAPWS Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam[]..1997
  • 4江浩,于新颖,郭俊文,常东锋,王浩,李欣,黄嘉驷,李杨,周元祥,谢天.低β值喉部取压喷嘴在给水流量测量中的应用[J].热力发电,2012,41(10):44-47. 被引量:6
  • 5.Performance Test Code 6OnSteam Turbines[].ASME/ANSIPTC—.

二级参考文献8

  • 1ASME/ANSI.Flow Measurement[].PTC.2004
  • 2Measurement of flow by means ofpressure differential devices inserted in circular crosssec-tion conduits running full—Part 2:Orifice plates. BS EN ISO 5167-2 . 2003
  • 3.Performance Test Code 6OnSteam Turbines[].ASME/ANSIPTC—.
  • 4.Proce-dure for Routine Performance Tests of Steam Turbines[].ASME PTCSReport- (reaffirmed).
  • 5B Bornstein,K C Cotton.A Simplified ASME AcceptanceTest Procedure for Steam Turbines[].Transactions ofthe ASME-Journal of Engineering for Power.1982
  • 6Benedict R P.Generalized Fluid Meter Discharge Coeffi-cient Based Solely on Boundary Layer Parameters[].ASME Journal of Engineering for Gas Turbines and Power.1979
  • 7Murdock,Keyser.Theoretical Basis for Extrapolation ofCalibration Data of PTC6Throat Tap Nozzles[].Journalof Engineering for Gas Turbine and Power.1991
  • 8Murdock,Keyser.A Method for Extrapolation of Calibra-tion Data of PTC6Throat Tap Nozzles[].Journal of En-gineering for Gas Turbine and Power.1991

共引文献5