摘要 总结分析了怠速状态下,汽车空调频繁启停化霜的常见原因。对某汽车空调系统进行了试验研究,结果发现:蒸发温度控制参数设置不当是其频繁启停的主要原因。通过分析蒸发温度控制参数对换热的影响,对该参数进行了优化设计。试验结果表明:蒸发温度控制参数优化设计后,空调系统运行性能良好,频繁启动的问题得到解决。 The common reason of frequent starting, stopping and defrosting of automobile air-conditioner at idle condition was summarized in the paper. Experimental study was carried out to one automobile air-condition system. According to the experiments, the improper setting of the parameter which control evaporating temperature was the main cause of frequent starting and stopping of automobile air-conditioner. By analyzing the influence on heat transfer of the parameter, the parameter was optimized. The experimental results show that the system works well and the problem of frequent starting of automobile air-conditioner is solved after optimizing the control parameter of evaporating temperature.
出处 《制冷技术》 2013年第2期30-32,共3页 Chinese Journal of Refrigeration Technology
关键词 怠速 汽车空调 结霜 频繁启动 Idle speed Automobile air-condition Frosting Frequent starting
  • 相关文献

参考文献4

二级参考文献12

  • 1Yao Y,Jiang Y Q,Deng S M,et al. A study on the per- formanee of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit [ J ]. Int. J. Heat Mass Transfer, 2004,47( 17 - 18) :3745 - 3756.
  • 2Senshu T,Yasuda H, Kuroda S, et al. Heat Pump Per- formance Under Frosting Conditions: Part1 - Heat and Mass Transfer on Cross - finned Tube Heat Exchangers Under Frosting Conditions [ J ]. ASHRAE Trans. , 1990,96( 1 ) :324 -329.
  • 3Tsoa C P,Cheng Y C. Dynamic behavior of a direct ex- pansion evaporator under frosting condition[ C]. Part I. Distributed model, International Journal of Refrigera- tion, 2006,29:611 - 623.
  • 4O' Neal D L, Tree D R. A review of frost formation in simple geometries [ J ] . ASHRAE Transactions. 1985, 91(2) : 267 - 281.
  • 5Sekhar. N, et al. Pertbrmance of finned tube heat exchangers under frosting conditions: Ⅱ comparison of experimental data with simulative data [ J ] . Int. J. Refrigeration,1993, 16(3) : 181 - 184.
  • 6Oskarsson S P. Evaporator models for operation with dry wet and frosted finned surfaces: part Ⅱ: Evaporator models and Verification[J]. ASHRAE, 1990,96(1) : 381-392.
  • 7Senshu T, Yasuda H. Heat pump performance under frosting condition: Part Two-Simulation of heat pump cycle characteristics under frosting conditions [ J ]. ASHARE Trans. 1990, 96( 1 ) : 330 - 336.
  • 8刘凤珍,陈焕新,连添达.影响翅片管换热器结霜因素的研究[J].低温工程,2000(4):45-48. 被引量:20
  • 9仲华,唐双波,陈芝久,刘维华,沈军.轿车空调蒸发器除霜实验研究[J].流体机械,2001,29(1):44-46. 被引量:12
  • 10刘凤珍,陈焕新,符建坤.低温工况下翅片管换热器结霜特性研究[J].流体机械,2002,30(11):54-57. 被引量:10