期刊文献+

Fabrication of the DNA/poly(3-methylthiophene) composite film modified electrode and its application for the study on the voltammetric behavior and determination of 8-hydroxy-2'-deoxyguanosine 被引量:2

Fabrication of the DNA/poly(3-methylthiophene) composite film modified electrode and its application for the study on the voltammetric behavior and determination of 8-hydroxy-2'-deoxyguanosine
原文传递
导出
摘要 A composite film of DNA/poly(3-methylthiophene)(P3MT) modified glassy carbon electrode(GCE) has been fabricated by electro-deposition method.P3MT film was first electropolymerized at the GCE and the DNA layer was then immobilized on the P3MT layer by electrochemical method.The voltammetric behavior of 8-hydroxy-2'-deoxyguanosine(8-OH-dG) at the composite film modified electrode was studied.The effects of scan rates,pH and the interference of uric acid(UA) on the voltammetric behavior and detection of 8-OH-dG were also discussed.The experimental results suggest that the electrochemical behavior of 8-OH-dG at the composite film modified electrode was greatly improved due to the combination of the advantages of P3MT and DNA.In 0.1 M pH 7.0 phosphate buffer solution(PBS),the anodic peak currents of 8-OH-dG were linear with the 8-OH-dG concentration in two intervals,viz.0.28―4.2 μM and 4.2―19.6 μM.The detection limit of 56 nM 8-OH-dG could be estimated(S/N=3).This proposed composite film modified electrode shows excellent reproducibility and stability.It may have the potential application for the detection of 8-OH-dG in human urine. A composite film of DNA/poly(3-methylthiophene)(P3MT) modified glassy carbon electrode(GCE) has been fabricated by electro-deposition method.P3MT film was first electropolymerized at the GCE and the DNA layer was then immobilized on the P3MT layer by electrochemical method.The voltammetric behavior of 8-hydroxy-2'-deoxyguanosine(8-OH-dG) at the composite film modified electrode was studied.The effects of scan rates,pH and the interference of uric acid(UA) on the voltammetric behavior and detection of 8-OH-dG were also discussed.The experimental results suggest that the electrochemical behavior of 8-OH-dG at the composite film modified electrode was greatly improved due to the combination of the advantages of P3MT and DNA.In 0.1 M pH 7.0 phosphate buffer solution(PBS),the anodic peak currents of 8-OH-dG were linear with the 8-OH-dG concentration in two intervals,viz.0.28―4.2 μM and 4.2―19.6 μM.The detection limit of 56 nM 8-OH-dG could be estimated(S/N=3).This proposed composite film modified electrode shows excellent reproducibility and stability.It may have the potential application for the detection of 8-OH-dG in human urine.
出处 《Science China Chemistry》 SCIE EI CAS 2009年第11期2006-2012,共7页 中国科学(化学英文版)
基金 Supported by the National Natural Science Foundation of China (Grant Nos. 20475024 & 20775031) the Shandong Tai-Shan Scholar Research Fund
关键词 poly(3-methylthiophene) DNA 8-hydroxy-2’-deoxyguanosine composite film modified electrode poly(3-methylthiophene),DNA,8-hydroxy-2'-deoxyguanosine,composite film modified electrode
  • 相关文献

参考文献42

  • 1XiangQinLIN XiaoHuaJIANG LiPingLU.DNA Nano-netting Intertexture on Carbon Electrodes[J].Chinese Chemical Letters,2004,15(8):997-1000. 被引量:2
  • 2Thompson L A,Kowalik J,Josowicz M,Janata J.Label-free DNA compositeization probe based on a conducting polymer. Journal of the American Chemical Society . 2003
  • 3Shigenaga M A,Ames B N.Assay for 8-hydroxy-2′-deoxyguanosine: A biomarker of in vivo oxidatve DNA damage. Free Radical Biology and Medicine . 1991
  • 4Kuo H W,Chou S Y,Hu T W,Wu F Y,Chen D J.Urinary 8-hydroxy-2′-deoxyguanosine (8-OH-dG) and genetic polymor- phisms in breast cancer patients. Mutation Research . 2007
  • 5Langmaier J,Samec Z,Samcová E.Electrochemical oxidation of 8-Oxo-2′-deoxyguanosine on glassy carbon,gold,platinum and Tin(Ⅳ) oxide electrodes. Electroanalysis . 2003
  • 6Goyal R N,Jain N,Garg D K.Electrochemical and enzymic oxidation of guanosine and 8-hydroxyguanosine and the effects of oxidation products in mice. Bioelectrochemistry and Bioenergetics . 1997
  • 7Rebelo I,Piedade J A P,Oliveira A M Brett.Electrochemical determination of 8-oxoguanine in the presence of uric acid. Bioelectrochemistry . 2004
  • 8O‘Neill M A,,Barton J K.DNA-mediated charge transport requires conformational motion of the DNA bases: Elimination of charge transport in rigid glasses at 77 K. Journal of the American Chemical Society . 2004
  • 9Delaney S,Barton J K.Charge transport in DNA duplex/quadruplex conjugates. Biochemical Journal . 2003
  • 10Lakhno V D,Sultanov V B,Pettitt B M.Combined hop- ping-superexchange model of a hole transfer in DNA. Chemical Physics Letters . 2004

二级参考文献4

  • 1[1]R. Holzel, N. Gajovic-Eichelmann, F. F. Bier, Biosensors and Bioelectronics, 2003, 18, 555.
  • 2[2]C. R. Treadway, M. G. Hill, J. K. Barton, Chem. Phys., 2002, 281, 409.
  • 3[3]Y. Zhao, D.W. Pang, S. Hu, Z. D. Wang, J. K. Cheng, H. P. Dai, Talanta, 1999, 49, 751.
  • 4[4]X. Q. Lin, L. P. Lu, X. H. Jiang, Microchem. Acta, 2003, in press.

共引文献1

同被引文献9

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部