摘要
根据山东电力调度中心对机组参与电网一次调频的要求,为验证发电机组DCS、DEH的一次调频逻辑、参数设置是否合理,2009年9月29日,对大唐鲁北发电厂330MW机组进行了各种工况下的一次调频功能试验,考察了该机组参与电网一次调频的特性。
According to the requirement of Shandong Electrical Power Dispatching Center for the units involved in the power grid's primary frequency regulation,in order to validate the rationality of generator sets' DCS and DEH in the logic of primary frequency regulation and parameter settings,September 29,2009,we conducted the function tests of primary frequency regulation for the 330MW unit of Datang Lubei power plant in a variety of operating conditions,which verified characteristics of the unit involved in the power grid's primary frequency regulation.
出处
《电气技术》
2010年第5期82-85,共4页
Electrical Engineering
关键词
电网
一次调频
DCS
DEH
逻辑
参数
the power grid
primary frequency regulation
DCS
DEH
logic
parameter