摘要
华东地区是亚热带气候,地源热泵的埋管换热效果等参数与北方地区不同,采用实地测量的方法研究了地源热泵系统在华东地区性能.结果表明,100 m单U型埋地管的每米孔深换热量为56 W/m,地源热泵系统全年总换热量为3 395 000.1 kWh,COP达到3.8,两年可收回系统初投资,是节能、经济的热泵系统.
East China is in subtropical climate region.Heat transfer effect and other parameters of ground-source heat pump pipe are different from those of North China.Based on field measurement,the performances of ground-source heat pump system in East China were analyzed.The results showed 100-meter single U-tube heat transfer was 56 W/m for each hole,the annual heat transfer of the ground-source heat pump system was 3 395 000.1 kWh,the COP reached 3.8,and the initial investment of the system could recover in two years.So this system was energy-efficient and economical heat pump system.
出处
《湖南大学学报(自然科学版)》
EI
CAS
CSCD
北大核心
2009年第S2期27-30,共4页
Journal of Hunan University:Natural Sciences
基金
国家863项目"复合冷凝热泵热水空调及冷热源新技术研究"(2006AA05Z229)
关键词
地源热泵
空调
华东地区
热泵系统
工程应用
ground source heat pump,air conditioning,east China
heat pump systems
engineering application