期刊文献+

地源热泵系统在华东地区的应用研究 被引量:6

The Utilization of Ground-source Heat Pump System in East China
下载PDF
导出
摘要 华东地区是亚热带气候,地源热泵的埋管换热效果等参数与北方地区不同,采用实地测量的方法研究了地源热泵系统在华东地区性能.结果表明,100 m单U型埋地管的每米孔深换热量为56 W/m,地源热泵系统全年总换热量为3 395 000.1 kWh,COP达到3.8,两年可收回系统初投资,是节能、经济的热泵系统. East China is in subtropical climate region.Heat transfer effect and other parameters of ground-source heat pump pipe are different from those of North China.Based on field measurement,the performances of ground-source heat pump system in East China were analyzed.The results showed 100-meter single U-tube heat transfer was 56 W/m for each hole,the annual heat transfer of the ground-source heat pump system was 3 395 000.1 kWh,the COP reached 3.8,and the initial investment of the system could recover in two years.So this system was energy-efficient and economical heat pump system.
出处 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S2期27-30,共4页 Journal of Hunan University:Natural Sciences
基金 国家863项目"复合冷凝热泵热水空调及冷热源新技术研究"(2006AA05Z229)
关键词 地源热泵 空调 华东地区 热泵系统 工程应用 ground source heat pump,air conditioning,east China heat pump systems engineering application
  • 相关文献

参考文献7

  • 1孙博,王坚飞,何荒震,郝玉龙.地源热泵空调技术及其在杭州的应用[J].浙江建筑,2008,25(1):51-55. 被引量:6
  • 2陈华清,周亚素,余红海.地源热泵技术的发展概况[J].科技信息,2007(28):14-14. 被引量:4
  • 3魏先勋,李元旦,林玉鹏,曾光明.土壤源热泵的研究[J].湖南大学学报(自然科学版),2000,27(2):62-65. 被引量:13
  • 4ZWARYCZ K,NOWAKW.Various mathematical models of heat transfer process in ground energy storage Bin. 9th Int Conf on Thermal Energy Storage . 2003
  • 5KHAN M H,VARANASIA,SPITLER J D, et al.Hybrid GSHP system simulation using visual modeling tool for HVACSIM. 8th Int IB PSA Conf . 2003
  • 6LUND IN S E,ER IKSSON B,BORRTEKN IK T, et al.Drilling in hard rock and borehole heat exchangers for seasonal stores. 9th Int Conf on Thermal Energy Storage . 2003
  • 7S. Kavanaugh.Water Loop Design for Ground-coupled Heat Pumps. ASHRAE Journal . 1996

二级参考文献18

  • 1陆跃庆.供暖通风设计手册[M].北京:中国建筑工业出版社,1987..
  • 2陆跃庆,供暖通风设计手册,1987年
  • 3章熙民,传热学,1985年
  • 4地下建筑暖通空调设计手册编写组,地下建筑暖通空调设计手册,1983年
  • 5B.R.Meloy.Free-Cooling Works for Cowlitz County Hall of Justice[].ASHRAE Transactions.1992
  • 6Jitendra B Singh,Gustav Foster,Arthur W Hunt.Representative Operating Problems of Commercial Ground-Source and Groundwater Source Heat Pumps[].ASHRAE Transactions.2000
  • 7Stevent Taylor.Determining Ventilation Rate:Revisions to Standard62-1989[].ASHARE Joural.1996
  • 8Hart D P.Earth-coupled heat transfer[].National Water Well Association.1986
  • 9Bose J E,Parker J D,McQuiston F C.Design/data manual for closed-loop heat pump systems[]..1985
  • 10V C Mei et al.Vertical Concentric Tube Ground-Coupled Heat Exchangers. ASHRAE trans,DC 83-08 .

共引文献19

同被引文献38

  • 1陈剑敏,田鸿雁.我国能源利用现状对发展低碳经济的制约与对策[J].改革与战略,2012,28(4):44-46. 被引量:6
  • 2王宇航,陈友明,伍佳鸿,彭建国.地源热泵的研究与应用[J].建筑热能通风空调,2004,23(4):30-35. 被引量:33
  • 3王书中,由世俊,张光平.热响应测试在土壤热交换器设计中的应用[J].太阳能学报,2007,28(4):405-410. 被引量:53
  • 4钟峰.LOW-E玻璃的节能特性[J].建筑节能,2007,35(5):42-43. 被引量:2
  • 5GB50366-2009地源热泵系统工程技术规范[S].北京:中国建筑工业出版社.2009.
  • 6GB 50366-2005地源热泵系统工程技术规范[S].
  • 7Kadir Bakirci. Evaluation of the performance of a ground-source heat-pump system with series GHE (ground heat exchanger) in the cold climate region[J]. Energy, 2010,35(7):3088-3096.
  • 8TRNSYS. TRNSYS 16-a transient system simulation program[R]. Madison, WI-USA: Solar Energy Laboratory, University of Wisconsin-Madison, 2006.
  • 9Desmedt J, Bael J V. Efficiency investigation and energy saving of vertical ground source heat pump [J].Strojarstvo, 2010,52 (4) : 405 - 409.
  • 10Lira K B, Lee S H, Lee C H. Application of ground- heat-source water*thermal-storage with a heat-pump cooling and heating systemEC] 7/Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 2010, 224 (El) : 73-78.

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部