期刊文献+

Analysis of Incidence of Atrial Fibrillation after Implantation of VVI Pacemaker-Long-term Observation of 154 Patients 被引量:7

Analysis of Incidence of Atrial Fibrillation after Implantation of VVI Pacemaker -Long-term Observation of 154 Patients
下载PDF
导出
摘要 Incidence of occurrence of atrial fibrillation (Af) after implantation of VVI was examined and the possible mechanism was explored. Eighty cases of atriouentricular block (AVB) and 74 cases of sick sinus syhdrome (SSS) were studied and followed up for 1-14 years after implantation of VVI. The endpoint was the occurrence of permanent Af. The results showed that the incidence of Af among the 154 patients was 14.3 % (22/154). And the incidence was 2. 5 % among patients with AVB (2/80), and 27 % among patients with SSS (20/74). Significant significance was found between patients with AVB and those with SSS (P<0. 01). Among the patients with SSS, the incidence was 33. 3 % (9/27) in type I, 38.1 % (8/21) in type Ⅲ and 11. 5 % (3/26) in type Ⅱ. Significant differences were revealed among patients with Ⅱ, Ⅲ and Ⅱ type SSS (P<0. 05). It is concluded that retrograde conduction of pure ventricular pacing may play the chief role of occurrence of Af. Incidence of occurrence of atrial fibrillation (Af) after implantation of VVI was examined and the possible mechanism was explored. Eighty cases of atriouentricular block (AVB) and 74 cases of sick sinus syhdrome (SSS) were studied and followed up for 1-14 years after implantation of VVI. The endpoint was the occurrence of permanent Af. The results showed that the incidence of Af among the 154 patients was 14.3 % (22/154). And the incidence was 2. 5 % among patients with AVB (2/80), and 27 % among patients with SSS (20/74). Significant significance was found between patients with AVB and those with SSS (P<0. 01). Among the patients with SSS, the incidence was 33. 3 % (9/27) in type I, 38.1 % (8/21) in type Ⅲ and 11. 5 % (3/26) in type Ⅱ. Significant differences were revealed among patients with Ⅱ, Ⅲ and Ⅱ type SSS (P<0. 05). It is concluded that retrograde conduction of pure ventricular pacing may play the chief role of occurrence of Af.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2000年第2期139-140,144,共3页 华中科技大学学报(医学英德文版)
关键词 ventricular demand pacing atrial fibrillation ventricular demand pacing atrial fibrillation
  • 相关文献

参考文献4

  • 1耿仁义,朱中林,李伯君.心房起搏的远期随访[J].中华心血管病杂志,1998,26(3):196-197. 被引量:10
  • 2段宝祥,耿其吉,戴国强,戴苏泉,查铭凡,黄进.植入VVI型起搏器伴心律失常62例分析[J].心脏起搏与心电生理杂志.1994(02)
  • 3Konings K T S,Kirchhof C J H J,Smeets J R L M etal.High density mapping of electrically induced atrialfibrillation in humans[].Circulation.1994
  • 4Sgarbossa E B,Pinski S L,Maloney J D et al.Chronicatrial fibrillation and stroke in paced patients with sick sinus syndrome.Relevance of clinical characteristics andpacing modalities[].Circulation.1993

共引文献9

同被引文献6

引证文献7

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部