期刊文献+

Beam Measurement System in NSRL 被引量:4

Beam Measurement System in NSRL
下载PDF
导出
摘要 This paper describes the beam measurement system for the accelerator of the National Synchrotron Radiation Laboratory (NSRL). The design considerations of the beam measurement instrumentation system for the NSRL are aided by the commissioning of the machine and provide sufficient machine parameters for machine study as well as the common operation. The beam measurement system includes the part for the linac and transport line and the part for the storage ring. The measurement results are presented in the paper. This paper describes the beam measurement system for the accelerator of the National Synchrotron Radiation Laboratory (NSRL). The design considerations of the beam measurement instrumentation system for the NSRL are aided by the commissioning of the machine and provide sufficient machine parameters for machine study as well as the common operation. The beam measurement system includes the part for the linac and transport line and the part for the storage ring. The measurement results are presented in the paper.
出处 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2000年第3期9-13,共5页 系统工程与电子技术(英文版)
基金 This project was supported by the sib Five Important Project on Science of Chinese Academy of Sciences.
关键词 Fluorescent screens Parameter estimation Synchrotron radiation Transport properties Fluorescent screens Parameter estimation Synchrotron radiation Transport properties
  • 相关文献

同被引文献23

  • 1Kurennoy S S, Sharer R E. Electromagnetic modeling of beam position monitors for SNS linac[A]. Proceedings of EPAC 2000[C]. Vienna,Austria, 2000, 8:1768--1770.
  • 2Kamikubota N, Obata T, Furukawa K, et al. Data acquisition of beam-position monitors for the KEKB injector-linac[A]. Proceedings of International Conference on Accelerator and Large Experimental Physics Control Systems[C]. Trieste, Italy, 1999. 217--219.
  • 3Suwada T, Kamikubota N, Fukuma H, et al. Stripline-type beam-position-monitor system for single-bunch electron/positron beam[J]. Nuclear Instruments and Methods in Physics Research, 2000, A440:307-319.
  • 4Yanagida K, Asaka T, Hanaki H, et al. A BPM system for the spring-8 linac[A]. Proceedings of the XX International Linac Conference[C]. California, 2000, 8:190--192.
  • 5Dehler M, Jaggi A , Kramert R, et al. Digital BPM system for the Swiss light source-first operational results[A]. AIP Conference Proceedings 546[C]. Cambridge, 2000: 572--574.
  • 6Shafer R E. Beam position monitoring[A]. AIP Conference Proceedings 212[C]. Upton, New York, 1989: 26--58.
  • 7Arinaga M,Flanagan J,Hiramatsu S,et al.KEKB beam instrumentation systems[J].Nuclear Instruments and Methods in Physics Research A,2003,499:100-137.
  • 8MA L,CAO J S,Wang L,et al.BEPC beam instrumentation system and its upgrade for BEPC Ⅱ[C]//The Second Asian Particle Accelerator Conference.Beijing:Institute of High Energy Physics,2001:698-700.
  • 9Yin Y.The beam diagnostics for Hefei SR Machine[C]//Proceedings of the International Conference on Synchrotron Radiation Applications.Hefei:University of Science and Technology of China Press,1989:265-269.
  • 10孙葆根,方志高,王贵诚,李辉,王筠华,谢荣胜,王霁虹,张丹红.合肥200MeV直线加速器的束流能谱测量系统[J].核技术,1998,21(1):48-50. 被引量:1