期刊文献+

气水雾化喷嘴最佳气水比的确定 被引量:11

OPTIMAL AIR TO WATER RATIO IN MISTING COOLING PROCESS
下载PDF
导出
摘要 从连铸喷雾冷却强度的控制因素入手,建立了冷却强度与水流密度、冲击速度、雾滴尺寸间的关系式。通过测定气水比对上述参数的影响,进而利用该关系式来计算冷却强度。结果表明,气水喷雾冷却过程存在最佳气水比值,但最佳气水比不是固定不变的,它随着水压的增加而减小。最佳气水比的确定对降低连铸二冷能耗具有重要的意义。 cooling efficiency in the continuous casting. Usually it could be got from experiments or the experience,but it would take high cost,long period and hard difficulty. In this paper,the factors for controlling intensity were analyzed. The relevant equation between cooling intensity and water rate of flow,impacting velocity,droplet size was built. And the cooling intensity was calculated by the equation. The results show that there is a optimal air to water ratio,yet it is variable and decease with water pressure increase. It is very significant to reduce the energy consumption of second cooling in continuous casting.
出处 《钢铁钒钛》 CAS 北大核心 2004年第2期49-51,70,共4页 Iron Steel Vanadium Titanium
基金 国家自然科学基金资助项目(50174021)。
关键词 连铸 冷却强度 气水比 喷雾冷却 能耗 continuous casting cooling intensity air to water ratio misting cooling energy consumption
  • 相关文献

参考文献6

  • 1Deb S,Yao S C.Analysis on Film Boling Heat Transfer of Impacting Spray[J].Int J Heat Mass Transfer,1989,32(11):2099-2112.
  • 2Moriyama A.Heat Transfer from Hot Steel Surface to a Water Droplet[J].Transactions ISIJ,1974,14:285-289.
  • 3Choi K J,Yao S C.Mechanisms of Film Boiling Heat Transfer of Normally Impacting Spray [J].Int J Heat Mass Transfer,1987,30(2):311-318.
  • 4Brimacombe J K,Agarwal P K,Baptista L A. Spray Cooling in the Continuous Casting of Steel[J]. Steel Proc,1980,63:235-252.
  • 5Stewart I, Massingham J D, Hagers J J. Heat Transfer Coefficient Effects on Spray Cooling [J].Iron and Steel Engineer, 1996,73(7):17-23.
  • 6者江,孙晗,李现昌,马重芳,雷道亨,贺春耕,田永权.水喷射淬冷高温壁面的传热实验研究[J].工程热物理学报,1997,18(5):629-633. 被引量:9