期刊文献+

高准确度标准电能表不同测量方式的测量误差 被引量:1

Measurement Error of High Veracity Reference Energy Meter in Diferent Measure Methods
下载PDF
导出
摘要 分析了采用标准电能表对三相三线电能表进行检验时,不同测量方式的优缺点。三表法测量无间断点,校验过程中需改变电流元件接线;矢量法采样精度高,校验时需标准表与系统电压中性点连接;两表法测量有间断点,校验时需改变电压元件接线。实验结果表明,三表法和矢量法比两表法相对误差较小。 Advantages and disadvantages of three methods of reference meter connection for measurement of three phase three wire energy meter are introduced.Three-meter method has no measure discontinuity but current component connectionneeds to be changed.Vector synthetic method has high measure precision but reference energy meter needs to be connected to zero point of reference meter and system.Two-meter method has measure discontinuity and voltage connection needs to be changed.The experiment results showed that three-meter method and vector synthetic method have more veracious than two-meter method.
出处 《河南科技大学学报(自然科学版)》 CAS 2004年第4期25-27,共3页 Journal of Henan University of Science And Technology:Natural Science
基金 河南省高等学校先进制造技术重点学科开放实验基金资助项目
关键词 电能表 测量方式 测量误差 两表法 三表法 矢量法 Energy meter Measurement method Measurement error
  • 相关文献

参考文献7

二级参考文献6

  • 1朱淑琴 黄寿海 等.电能计量录象教材配套讲义[M].能源部电力司,1989..
  • 2林炳海 方吉六.用对称分量法分析三相电路中功率和电能的测量误差[J].电测与仪表,1975,(8):17-24.
  • 3.JJG596-1999.电子式电能表[S].北京:中国计量出版社,1999..
  • 4JJG307-88交流电度表检定规程[S].中国计量出版社.
  • 5蓝永林.交流电度表检定与调整[M].中国计量出版社,1985.
  • 6宁金铭.浅谈低压无功动态补偿装置[J].电力电容器,2001(3):24-26. 被引量:2