摘要 建立了用能量色散X荧光仪同时测定Co,Mn,Br 3种共存元素的新方法。优化了操作条件,讨论了影响因素,考察了方法的精密度和准确度。其中Co回收率为95.3%-103.0%,Mn回收率为96.0%-104.0%,Br回收率为94.8%-105.0%。用于精对苯二甲酸化工装置试样中Co,Mn,Br的同时测定,结果满意。 <abstract>new method for simultaneous determination of Co Mn and Br in plant sample by X - ray fluorescene spectrometer was studied. Optimum experiment conditions, factors interfering experiments accuracy and precision of the method were investigated. Recovery rates of the three elements were as followed: Co 95.3%-103.0%, Mn 96.0%-104.0%, and Br 94.8%-105.0%. The proposed method has been satisfactorily applied to analysis of Co,Mn,Br in samples from purified terephthalic acid plant.
出处 《石油化工》 CAS CSCD 北大核心 2004年第7期673-676,共4页 Petrochemical Technology
关键词 X荧光 元素 对苯二甲酸 <keyword>ray fluorescene Co Mn Br element terephthalic acid
  • 相关文献

参考文献7

  • 1Subert J, Havlickova B. Quantitative Evaluation of Drugs in PhBs Ⅲ /PhBsⅣ. Farm Obz, 1988,57(8) :345- 352
  • 2Szczepaniak Walentry. Potentiometric - Mercurimetric Titration of Halides, Thiourea and Mercaptans Using an Iion-Selective Electrode Sensitive to Mercury(2 + ) Ions. Chem Anal, 1988,33(4) :491 -496
  • 3ASOMA Instruction USA:Published by Spectro ,January 20,2000
  • 4袁仲全.天津PTA装置试车简介[J].聚酯工业,2000,13(3):31-34. 被引量:5
  • 5GB223.64-88.火焰原子吸收光谱法测定锰量.[S].,..
  • 6GB223.64-88.火焰原子吸收光谱法测定钴量.[S].,..
  • 7杭州大学化学系分析化学教研室编.分析化学手册,第三分册,电化学分析与光学分析[M].北京:化学工业出版社,1984..