期刊文献+

电气设备实施状态维修决策方法的探讨 被引量:88

DISCUSSION ON MAKING DECISION ABOUT ELECTRIC EQUIPMENT FOR CONDITION BASED MAINTENANCE
下载PDF
导出
摘要 摘要:以状态维修逐步取代定期维修已成为电气设备检修的必然趋势,但在复杂大型电网中如何合理选择电气设备开展状态维修工作,如何成功地向状态维修过渡,仍是许多输变电企业在实际检修工作中面临的主要难题。文中考虑到状态维修所需的技术支持、设备状况和人员素质等多方面因素,基于输变电企业现有的技术条件和管理水平,提出了一个依据专家对已知信息做出的决策,应用模糊综合评价方法判断电气设备可否实施状态维修的基本思路。 It is an inexorable trend to replace the traditional periodical maintenance with condition based maintenance (CBM) progressively, but the main difficulty that many power transmission and transformation enterprises will face with is how to rationally choose the equipments to develop the CBM in large complicated power grids and how to successfully realize the transition from current situation mode of equipment maintenance to CBM. Considering the factors such as technical support needed by CBM and the personal performance and so on, and on the basis of existing technological condition and management level, a thinking of whether power equipments can be brought into CBM or not is put forward according to the experts' decision on known information and using fuzzy comprehensive evaluation.
作者 田玲 邢建国
出处 《电网技术》 EI CSCD 北大核心 2004年第16期60-63,共4页 Power System Technology
关键词 电气设备 决策方法 决策方法 状态维修 模糊综合评价理论 模糊数学 Decision making Electric power systems Fuzzy sets Maintenance Power transmission
  • 相关文献

参考文献6

二级参考文献35

  • 1张喜林,宋家骅,任先文,王克英,戴伏生.电容型设备绝缘在线监测参数的修正计算[J].东北电力学院学报,1994,14(2):1-7. 被引量:9
  • 2蔡国雄,胡兆明,王建民.介质损耗测量的过零点电压比较法[J].电网技术,1995,19(10):1-5. 被引量:35
  • 3田卫东.以高阶累积量和高阶正交多项式级数展开式为基础的电力生产随机概率模拟方法[J].电网技术,1995,19(1):31-34. 被引量:39
  • 4赵秀山,谈克雄,朱德恒,李福祺.介质损耗角的数字化测量[J].清华大学学报(自然科学版),1996,36(9):51-56. 被引量:44
  • 5国家电力公司.火力发电厂实施设备状态维修的指导意见[M].,2001..
  • 6M Di Lorenzo,R Schifani ,J T Holboll. Partial Discharge Tests Using CIGRE Method Ⅱ [J]. IEEE Trans on IEEE transactions on Dielectrics and Electrical Insulation, 2000, 7 ( 1 ), 133-140.
  • 7Djokic B, So E. Phase measurement of distorted periodic signals based on nonsynchronous digital filtering[J]. IEEE Transactions on Instrumentation and Measurement, 2001, 50(4): 864-867.
  • 8Allan D, Blundell M, Boyd K et al. New techniques for monitoring the insulation quality of in-service HV apparatus[J]. IEEE Transactions on Electrical Insulation, 1992, 27(3): 578-581.
  • 9Wang Pei, Raghuveer M R, McDermid W et al. A digital technique for the on-line measurement of dissipation factor and capacitance[J]. IEEE Transactions on Dielectric and Electrical Insulation, 2001, 8(2):228-232.
  • 10赖庆波,供电设备状态维修三年实践初步总结,1995年

共引文献690

同被引文献223

引证文献88

二级引证文献377

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部