摘要 Extinetion positions can be rapidly and accurately determined with interference figures by adjusting the isogyres to the position bisected by eross wire intersection,The accuracy of this method is 0.1 to 0.3°,corresponding the toat obtained by Nakamura plate.This method can be used in combination with universal stage,but is also applicable with spindle stage or ordinary petrograaphic microscope. Extinction positions can be rapidly and accurately determined with interferencefigures by adjusting the isogyres to the position bisected by cross wire intersection.The accuracy of this method is 0.1 to 0.3°, corresponding to that obtained by Naka-mura plate This method can be used in combination with universal stage, but is alsoapplicable with spindle stage or ordinary petrographic microscope.
作者 苏树春
机构地区 甘肃第六地质队
出处 《地球化学》 CAS 1978年第4期303-307,共5页 Geochimica