摘要
结合邯郸热电厂循环水补充水的水质特点、深度处理工艺和循环水系统发生的问题,对冲击加入杀菌剂导致的pH下降的机理进行了分析,提出了相应的解决方案。
According to the features of make up water of circulating water, finishing procedure of the water and the problems circulating water encountered, the authors analyze why the mechanism of the pH of circulating water drops after adding bactericide and propose some solutions accordingly.
出处
《河北电力技术》
2004年第4期50-51,共2页
Hebei Electric Power
关键词
电厂
循环水处理
杀菌剂
pH下降
power plant
circulating water treatment
bactericide
pH drops