期刊文献+

关于研制X射线荧光微分析标准物质的探讨 被引量:2

Study on Microanalysis Reference Material for X-Ray Fluorescence Analysis
下载PDF
导出
摘要 将经过高温处理的土壤样品进行反复研磨后,用于X射线荧光微分析标准物质的研制,当99%的粉末粒径≤30μm时,用仪器中子活化和同步辐射X射线荧光进行元素分布均匀性和最少取样量分析,结果表明24个元素的最少取样量可以降到约1mg。 Preparation of a microanalysis reference material (MRM) for X-ray fluorescence analysis was reported in this paper.A soil sample was pretreated under high temperature and grinded repeatedly until 99% of the sample powder is ≤ 30 μm in size. Neutron activation analysis (NAA) and synchrotron radiation X-ray fluorescence spectrometry (SRXRF) techniques were used for sample homogeneity test. The analytical results show that the sample is homogeneous and the minimum analytical masses for microanalysis of K, Ca, Ti, Mn, Fe, Zn, Rb, Sr, Sc, Cr, Co, Rb, Cs, La, Ce, Nd, Sm, Tb, Yb, Lu, Hf, Ta, Th, U by XRF is 1 mg.
出处 《岩矿测试》 CAS CSCD 北大核心 2004年第3期179-182,共4页 Rock and Mineral Analysis
基金 国家自然科学基金项目(10075060 10135050) 中国科学院知识创新项目(KJCX-N04) 国家同步辐射实验室项目
关键词 土壤学 X射线荧光微分析 微分析标准物质 仪器中子活化 microanalysis reference material neutron activation analysis synchrotron radiation X-ray fluorescence spectrometry
  • 相关文献

参考文献4

  • 1Kane J S,Potts P J.An Interpretation of ISO Guidelines for the Certification of Geological Reference Materials[J].The Journal of Geostandards and Geoanalysis.1999,23(2):209-221.
  • 2Kane J S.Reference Samples for Use in Analytical Geochemistry:Their Availability,Preparation and Appropriate Use[J].Journal of Geochemical Exploration.1992,44:37-63.
  • 3Kane J S.Homogeneity of Reference Materials Analyst[J].The Analyst.1997,122:1289-1292.
  • 4Kane J S.An Assessment of the Suitability of NIST Glass SRM Literature Data for the Derivation of Reference Values[J].The Journal of Geostandards and Geoanlaysis.1998,22(1):15-31.