期刊文献+

CT灌注成像在肾癌预后评估方面的应用价值 被引量:11

CT perfusion imaging in evaluating renal carcinoma
下载PDF
导出
摘要 目的 探讨CT灌注成像在评估肾癌预后和术式选择等方面的应用价值。方法  2 0例肾癌患者 ,根据临床分期分成局限组和转移组 ;根据病理分级分成低度活性组和中高度活性组 ,及健康自愿者 3 0人进行肾区CT平描 ,之后选择经肾门或肿瘤的最大层面进行动态增强扫描 ,应用感兴趣区域分析法 ,计算正常肾皮质和肾癌组织的灌注值。结果 转移组肾癌灌注值显著高于局限组 (t检验 ,P =0 .0 15 ) ,中高度活性组肾癌灌注值亦显著高于低度活性组 (t检验 ,P =0 .0 14 )。结论 CT灌注成像在评估肾癌预后和术式选择等方面具有一定的临床应用价值。 Objective To discuss the value of CT perfusion imaging in evaluating renal cell carcinoma (RCC). Methods CT perfusion was performed in 30 healthy subjects and 20 cases of RCC to obtain the time-density curves of nomal renal cortex and RCC. A single slice through the renal hili or tumor was scanned after the intravenous injection of 40~50 ml of contrast given at 5ml/s. Thirty scans were performed from 8 to 37s after injection at 0.5 s duration and 0.5 s interval. Time-density curves were then drawn for both kidneys or renal tumor and aorta using regions of interest (ROIs). Perfusion was calculated as the peak upslope of the tissue time-density curve divided by peak aortic enhancement. All 20 cases of RCC were divided into two groups based on clinical stages: local group (12 cases) and metastatic group (8 cases), and were divided into two other groups based on pathological stages: low grade group (11 cases) and middle or high grade group (9 cases). Results Renal cortical perfusion of healthy subjects was (2.68±0.40) ml/(min·ml), and perfusion of RCC was (1.51± 0.68 ) ml/(min·ml). Perfusion of metastatic group was significantly higher than that of local group ( t test, P =0.015 ), and perfusion of middle or high grade group was also significantly higher than that of low grade group ( t test, P =0.014). Conclusion CT perfusion imaging is valueable in evaluating RCC.
出处 《中国医学影像技术》 CSCD 2004年第9期1403-1405,共3页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 灌注 肾癌 Tomography, X-ray computed Perfusion Kidney Renal cancer
  • 相关文献

参考文献15

  • 1Axel L. Cerebral blood flow determination by rapid sequence computed tomography[J]. Radiology, 1980, 137(3): 679-686.
  • 2Konig M, Klotz E, Heuser L. Perfusion CT in acute stroke: characterization of cerebral ischemia using parameter images of cerebral blood flow and their therapeutic relevance[J]. Clinical experiences, Electromedica, 1998, 66(1): 61-67.
  • 3Konig M, Klotz E, Luka B, et al. Perfusion CT of the brain: diagnostic approach for early detection of ischemia stroke[J]. Radiology,1998, 209(1): 85-93.
  • 4Wolfkiel CJ, Ferguson JL, Chomka EV, et al. Measurement of myocardial blood flow by ultrafast computed tomography[J]. Circulation, 1987, 76(6): 1262-1273.
  • 5Miles KA, Hayball MP, Dixon AK. Functional images of hepatic perfusion obtained with dynamic CT[J]. Radiology, 1993, 188(2): 405-411.
  • 6Blomley MJK, Coulden R, Bufkin CRT, et al. Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion[J]. Invest Radiol, 1993, 28(Suppl5): S72-S77.
  • 7Miles KA, Hayball MP, Dixon AK. Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging[J]. Br J Radiol, 1995, 68(809): 471-475.
  • 8Blomley MJK, Kormano M, Coulden R, et al. Renal perfusion quantified with contrast enhanced computed tomography[J]. Invest Radiol, 1994, 29(2): S232-233.
  • 9Miles KA, Hayball MP, Dixon AK. Functional images of changes in human intarenal perfusion using quantitative dynamic computed tomography[J]. Invest Radiol, 1994, 29(10): 911-914.
  • 10Blomley MJK, Mcbride A, Mohaecltagi S, et al. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)[J]? Eur J Radiol, 1999, 30(3): 214-220.

同被引文献137

引证文献11

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部