介绍厦门某小高层公寓工程采用预制混凝土方桩基础,静压施工过程桩身倾斜度偏差超过规范规定;通过对倾斜桩的承载力进行计算分析,并采取了相应的技术处理措施,使本来存在倾斜缺陷的桩在保证结构安全的基础上得以合理使用的成功实例。
the declining level of some prefabricate quadrate piles of a highrise residential building in xiamen city go beyond the limit in driving process, this is an example of using the declining piles reasonably based on structure security by analyzing the bearing capacity of the declining piles and taking corrsponding measures