期刊文献+

低温热利用节能改造 被引量:9

ENERGY CONSERVATION REVAMPING TO UTILIZE LOW TEMPERATURE HEAT
下载PDF
导出
摘要 介绍济南分公司实施全厂低温热利用节能改造情况 ,通过调整两套催化裂化装置的换热流程 ,利用取出的低温热作为气分装置脱乙烷塔底、脱丙烯塔底重沸器热源 ,替代 1.0MPa蒸汽 ,节能效果十分显著。并对脱轻碳四塔底重沸器热源用低温热进行了试验 ,效果良好。 Energy conservation revamping to utilize low temperature heat in Jinan Company is expounded. Heat exchange flows of two FCC units have been regulated and low temperature heat removed from the units was used as heat source for bottom reboilers of deethanizer and depropanizer in light ends plant to replace 1.0 MPa steam. Evident effect has been obtained. In addition, low temperature heat used as the heat source for bottom reboilers of C 4 fractionator has been tested and the effect is excellent.
作者 吕亮功
出处 《炼油技术与工程》 CAS 北大核心 2004年第9期60-62,共3页 Petroleum Refinery Engineering
关键词 塔底 碳四 重沸器 丙烯 脱乙烷塔 替代 节能改造 换热流程 催化裂化装置 节能效果 catalytic cracking unit, light-ends plant, low temperature heat, energy conservation, revamping