三台分列运行的三绕组变压器,中压侧与低压侧共有六个负载,三台变压器间的负载可以互相调整。因此三台三绕组变压器间通过负载的相互调整可实施分列运行、并列运行与不同台数组合运行方式共计289种。分析计算了这289种运行方式中的经济运行,并举例给出其节电效果。
There are six loads in mid-voltage and low-voltage sides of three sets of splitting three-winding transformers, whose loads can be regulated mutually. So totaled 289 kinds of operation modes are presented, such as load adjusting, splitting, parallel and different sets combination etc,among the three transformers. The economic operation of the 289 kinds of modes are analyzed and accounted. The economic effects on energy consumption are demonstrated with examples.
出处
《继电器》
CSCD
北大核心
2004年第20期28-33,共6页
Relay