摘要
针对SS8型机车大修后停车制动力不够的现象,分析其故障原因,并提出了相应的改进措施。经实际运行考核验证,该改进很有效。
This paper analyses the cause that type SS8 electric locomotives have no enough parking brake force after heavy repairing,and presents improvement measures. Actual running tests validates the improvement is effective .
出处
《电力机车与城轨车辆》
2004年第6期15-16,共2页
Electric Locomotives & Mass Transit Vehicles
关键词
SS8型机车
蓄能制动器
活塞行程
改进
type SS8 electric locomotive
power storage brake
piston stroke
improvement