根据高频电力的特性及手术室的物理环境 ,分析了高频电刀灼伤病员皮肤的状况 ,讨论了存在的问题和原因 ,提出了解决问题的建议。
From characteristics of electrosuigical generator and physical environment of surgical room,this paper analyzes the status of burn skin of electrosurgical generator in surgery,discusses the prolems and their causes,and puts forward the suggestions to solve the problems.