期刊文献+

500kV变电站TCR-Based SVC的技术改进方向探讨 被引量:2

Discussion on technical improvement direction of the TCR-based SVC in 500 kV substations
下载PDF
导出
摘要 以电网安全优质经济运行为目的,基于当代SVC的发展状况,以500kV云田变电站TCR-BasedSVC为例,探讨我国500kV变电站(5地)6套TCR-BasedSVC的技术改进方向,结论是用国产MCR替代TCR,组成MCR-BasedSVC是上策。 This paper presents and discusses the technical improvement direction of six sets of the TCR-Based SVC distributed in five 500 kV substations in China by using the example of the TCR-Based SVC in the 500 kV Yuntian Substation. It concludes that based on the contemporary development of SVC, it is optimal to compose MCR-Based SVC by using domestic MCR instead of TCR in order to make the grid operation safe and economical.
作者 蒋凯 唐寅生
出处 《电力技术(北京)》 CSCD 北大核心 2004年第12期27-30,共4页
  • 相关文献

参考文献4

二级参考文献3

  • 1Janke A. Experience with SVCs and stratcgies for operation and msintenance of SVCs in the future[C]. CIGRE, Regional Meeting Conference Papers, 1993.
  • 2陈伯超.新型可控饱和电抗器理论及应用[M].武汉:武汉水利电力大学出版社,1999..
  • 3蔡超豪.静止无功补偿器的非线性H_∞控制[J].电网技术,2002,26(6):36-38. 被引量:7

共引文献39

同被引文献17

引证文献2

二级引证文献30