摘要
以电网安全优质经济运行为目的,基于当代SVC的发展状况,以500kV云田变电站TCR-BasedSVC为例,探讨我国500kV变电站(5地)6套TCR-BasedSVC的技术改进方向,结论是用国产MCR替代TCR,组成MCR-BasedSVC是上策。
This paper presents and discusses the technical improvement direction of six sets of the TCR-Based SVC distributed in five 500 kV substations in China by using the example of the TCR-Based SVC in the 500 kV Yuntian Substation. It concludes that based on the contemporary development of SVC, it is optimal to compose MCR-Based SVC by using domestic MCR instead of TCR in order to make the grid operation safe and economical.