期刊文献+

肾动态显像法与双血浆法测定肾小球滤过率的对比分析 被引量:32

Measurement of glomerular filtration rate with renal dynamic imaging:comparison with two-sample method
下载PDF
导出
摘要 目的:对肾动态显像法测定肾小球滤过率(glomerular filtration rate,GFR)与双血浆法进行比较,以评价肾动态显像法测定肾小球滤过率的可靠性。方法:原发或继发慢性肾脏病患者54例,按常规方法进行肾动态显像,采用仪器中的处理程序(Gates 法)进行图像处理得到 GFR;静脉注射锝-99m-二乙三胺五乙酸(^(99)Tc^m-DTPA)后2h 及4h 取血,测定1mL 血浆中的放射性计数,用双血浆法计算公式求得 GFR,对肾动态显像法与双血浆法测的GFR 进行相关性分析,并比较两者测得的 GFR 与血清尿素(urea)及肌酐(creatinine,Cr)水平的关系。结果:肾动态显像法与双血浆法测得的 GFR 值具有良好的相关性(r=0.881 5,P<0.01),两者的直线回归方程为,GFR(肾动态显像法)=0.661 4 GFR(双血浆法)+21.89;肾动态显像法与双血浆法测得的 GFR 与 urea 及 Cr 的相关性直线相近,表明二者几乎以相同的数量关系反映肾功能的变化;2例偏瘦的病人和1例偏胖的病人两种方法测得的GFR 差异较大。结论:一般情况下肾动态显像法测得的 GFR 能够可靠地反映肾功能的变化,与双血浆法测得的GFR 相符合,但对于特殊体形的患者,肾动态显像法测得的 GFR 可能会有较大的偏差。 Objective:To compare the estimation of glomerular filtration rate(GFR)by renal dynamicimaging with that estimated by two-sample method and evaluate the reliability of measurement of GFR byrenal dynamic imaging.Methods:The study was performed in 54 patients(33 males and 21 females;aged 15 to 82 years)with primary or secondary chronic nephrosis.The patients were intravenously bolusinjected with 185 MBq/1 mL of (99)~Tc^m-DTPA 20 min after drinking 300 mL of water.Renal dynamic ima-ging was performed and the image was processed according to standard procedure(Gates' method)to ob-tain GFR.3mL of blood was withdrawn 2h and 4h postinjection,respectively,and radioactivity of 1mLplasma was measured.GFR was calculated by the formula of two-sample method.The correlation ofGFRs measured by renal dynamic imaging and by two-sample method was analyzed using regression anal-ysis.The correlations of GFRs determined by the two methods with urea and creatinine were also meas-ured.Results:The GFR measured by renal dynamic imaging was slightly lower than that measured bytwo-sample method.Excellent correlation was obtained by two methods with r=0.881 5 and P<0.01.The linear regression equation was GFR(renal dynamic imaging method)=0.661 4GFR(two-samplemethod)+21.89.The related lines of GFRs measured by the two methods with urea or creatinine weresimilar,which indicated the two methods were similar in identifying the changes in renal function.GFRsmeasured by the two methods showed good agreement for most of patients except three patients who weretoo thin or too fat.Conclusion:Generally,GFR obtained by renal dynamic imaging is reliable for identi-fying the changes in renal function and correlated well with GFR obtained by two-sample method.Butgreat error may be obtained with specific individuals,such as too thin or too fat subjects.
出处 《北京大学学报(医学版)》 CAS CSCD 北大核心 2004年第6期612-615,共4页 Journal of Peking University:Health Sciences
关键词 GFR 肾动态显像 浆法 血浆 肾小球滤过率 肾功能 患者 数量关系 直线 结论 Glomerular filtration rate Renal artery/radionuclide two-sample method
  • 相关文献

参考文献10

  • 1Blaufox MD,Aurell M,Bubeck B,et al. Report of the radionuclides in nephrourology committee on renal clearance [ J ]. J Nucl Med,1996, 37: 1883 - 1890
  • 2Durand E, Prigent A. The basics of renal imaging and function studies[J]. Q J Nucl Med, 2002, 46:249 -267
  • 3Petersen LJ, Petersen JR, Talleruphuus U, et al. Glomerular filtration rate estimated from the uptake phase of 99 mTc-DTPA renography in chronic renal failure [ J ]. Nephrol Dial Transplant, 1999 , 14:1673 - 1678
  • 4Russell CD. Optimum sample times for single-injection, multisample renal clearance methods[ J]. J Nucl Med, 1993, 34:1761 - 1765
  • 5Itoh K,Tsushima S,Tsukamoto E, et al. Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA[J]. Ann Nucl Med, 2002, 16:39 -44
  • 6Waller DG, Keast CM, Fleming JS, et al. Measurement of Glomerular Filtration Rate with Technetium-99m DTPA: comparison of Plasma Clearance Techniques[J]. J Nucl Med, 1987, 28:372 -377
  • 7Piepsz A, Dobbeleir A, Erbsmann F. Measurement of separate kidney clearance by means of 99mTc-DTPA complex and a scinitillation camera[J]. Eur J Nucl Med, 1977, 2:173 - 177
  • 8Gates FG. Glomerular filtration rate: estimation from fractional renal accumulation of 99mTc-DTPA[ J]. Am J Roentgenol, 1982, 138:565- 570
  • 9Inoue Y, Ohtake T, Homma Y, et al. Evaluation of glomerular filtration rate by camera-based method in both children and adults [ J ].J Nucl Med, 1998,39: 1784-1788
  • 10Itoh K,Tsushima S,Tsukamoto E, et al. Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA[J]. Ann Nucl Med, 2000, 14:143- 150

共引文献1

同被引文献229

引证文献32

二级引证文献189

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部