多层螺旋CT冠状动脉成像的临床应用 被引量:2

Multi-slice spiral CT coronary angiograghy:technique and initial clinical application
下载PDF
导出
摘要 目的 :评价多层螺旋CT(MSCT)对冠状动脉的显示能力及对冠状动脉狭窄的诊断价值。 方法 :对 5 2例可疑冠心病患者行MSCT冠状动脉成像 ,其中 2 8例 1周内行选择性冠状动脉造影检查 ,并对检查结果进行分析和评价。 结果 :5 2例患者共显示 5 11个血管节段 ,其中 82 %的血管节段具有影像诊断价值。MSCT诊断≥ 5 0 %冠脉狭窄程度的敏感性为 70 .97% ,特异度为 98.75 % ,阴性预测值为 96 .34%。 结论 :MSCT冠状动脉成像是一项有潜力的、无创性的检查方法 ,适用于心率较慢患者冠心病的筛查。 Objective: To evaluate the ability of Multi-slice spiral CT (MSCT) on display of coronary artery and the feasibility of MSCT in diagnosis of coronary stenosis. Methods: 52 patients with suspected coronary heart disease and 3 patients underwent MSCT coronary angiography. 28 of them were also investigated with selective coronary angiography (SCA). Results: With MSCT angiography, 82% coronary segments were assessable. The sensitivity for diagnosing significant coronary stenosis (≥50% lumen reduction) was 70.97%, the specificity was 98.75%. The negative predictive value was 96.34%. Conclusion: MSCT coronary angiography, non-invasive、 convenient and reliable, is a potential method for screening coronary artery disease and following-up post-operative PTCA, especially in patients with low heart rates.
出处 《新疆医科大学学报》 CAS 2004年第6期563-565,共3页 Journal of Xinjiang Medical University
关键词 冠状动脉造影术 体层摄影 X-线计算机 coronary angiography tomography, X-ray computed co ronary disease
  • 相关文献

参考文献4

  • 1赵绍宏,聂永康,蔡祖龙,赵红,杨立.冠状动脉疾病多层面螺旋CT成像初探[J].中华放射学杂志,2002,36(8):712-715. 被引量:87
  • 2Nieman K, Rensing BJ, Vos J, et, al. Noninvasive coronary angiography with multislice spiral computed tomography: impact of heart rate[J]. Heart. 2002, 88:470-474.
  • 3Becker CR, Knez A, Leber A, et al. Initial experiences with multi-slice detector spiral CT in diagnosis of coronary vessels[J]. Radiology, 2000, 40:118-122.
  • 4Ohnesorge B, Flohr T, Becher C, et al. Cardiac imaging with rapid, retrospective ECG synchronized multilever spiral CT[J]. Radiology, 2000, 40:111-117.

二级参考文献2

共引文献86

同被引文献13

  • 1王锡明,武乐斌,李振家,柳澄,陈海松.64层螺旋CT在冠状动脉造影中的应用[J].中华放射学杂志,2005,39(11):1201-1204. 被引量:150
  • 2刘斌,赵红,吴兴旺,张家文,余永强,廖静敏.64层螺旋CT冠状动脉成像图像质量的相关影响因素分析(心脏体模模拟实验)[J].中华放射学杂志,2006,40(9):980-983. 被引量:38
  • 3Kuettner A, Beck T, Drosch T, et al. Image quality and diagnostic accuracy of non invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution. Heart, 2005,91(7):938-941.
  • 4Brodoefel H, Reimann A, Heuschmid M, et al. Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high rates. Radiology, 2006,16(7): 1434-1441.
  • 5Raff GL. Gallagher MJ, O' Nell WW. et al. Diagnostic accuracy of non-invasive coroaary angiography using 64-slice spiral compuled tomography. J Am Coll Cardiol, 2005,,16(3):552-557.
  • 6Giesler T, Baurn U, Ropers D, et al. Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. Am J Roentgenol AJR, 2002, 179(4) :911-916.
  • 7Hoffmann MH, Shi H, Manzke R, et al. Noninvasive coronary angiography with 16-detector row CT: effect of heart rate. Radiology, 2005,234(1) :86-97.
  • 8Kopp AF, Schroder S, Kuettner A, et al. Cornary arterier: retrospectively ECG-gated multi-detecter row CT angiography with selective optimization of the image reconstruction window. Radiology, 2001,221(3) :683-688.
  • 9Kuettner A, Beck T, Drosch T, et al. Image quality and diag nostic accuracy of non-inwasive coronary imaging with 16 detctot slice spiral computed tomography with 188 ms temporal resolution[J]. Heart ,2005.91:938-941.
  • 10Wang K, Hou Y. Scaning method of multi spiral CT angiography of coronary artery [J]. Chin J Med Imaging Technol , 2003,19(9) :1239-1241.