期刊文献+

下肢动脉MRA检查方法的比较研究 被引量:1

Comparative study of MRA techniques in the infrapopliteal arteries
下载PDF
导出
摘要 目的:探讨幅度对比法磁共振血管造影(magnitudecontrastmagneticresonanceangiography,MCMRA)、二维时间飞跃法磁共振血管造影(2Dtimeofflightmagneticresonanceangiography,2DTOFMRA)、滑动间隔Ky(SlidinginterleavedKY,SLINKY)采集的三维时间飞跃法磁共振血管造影(3Dtimeofflightmagneticresonanceangiography,3DTOFMRA)在腘以下动脉的应用价值。方法:健康志愿者14名,采用MCMRA、2DTOFMRA、SLINKY采集3DTOFMRA三种方法进行双侧腘以下动脉检查,并对图像质量进行比较分析。结果:MCMRA法背景抑制好,时间短,但无法去除静脉影像。2DTOFMRA显示血管清晰、均匀,血管分支显示较好。3DTOFMRA血管显示接近2DTOFMRA,但检查时间较长。结论:2DTOFMRA可作为腘以下动脉常规MRA的首选。 Objective:To explore the value of MC MRA, 2D TOFMRA, and Sliding interleaved ky(SLINKY) acquisition for 3D TOFMRA in the infrapopliteal arteries. Methods:Three kinds of MRA were performed in the low leg of fourteen volunteers. The quality of three kinds of pictures was compared and analyzed. Results: MC MRA cost least time,and restrained background noise well. But MC MRA could not remove the veins. The vessels including branches could be shown clearly and uniformly with 2D TOF MRA. 3D TOF MRA showed the vessels closely resembling 2D TOF MRA, but cost more times. Conclusion:2D TOF MRA should be the preferred routine MRA in the exam of the the infrapopliteal arteries.
出处 《南京医科大学学报(自然科学版)》 CAS CSCD 北大核心 2005年第3期194-196,共3页 Journal of Nanjing Medical University(Natural Sciences)
关键词 下肢动脉 磁共振成像 血管造影 low limb artery magnetic resonance imaging angiography
  • 相关文献

参考文献15

  • 1徐海波,孔祥泉,杨亚莉,肖学宏,熊茵,刘定西,杨帆,于群.多种MR血管造影对四肢血管性疾病和血管狭窄模型的应用研究[J].中华放射学杂志,2001,35(9):708-712. 被引量:14
  • 2Morasch MD, Collins J, Pereles FS, et al. Lower extremity stepping-table magnetic resonance angiography with multilevel contrast timing and segmented contrast infusion [ J ]. J Vasc Surg, 2003,37 ( 1 ): 62-71.
  • 3Khilnani NM, Winchester PA,Prince MR,et al. Peripheral vascular disease :combined 3D bolus chase and dynamic 2D MR angiography compared with X-ray angiography for treatment planning[J]. Radiology,2002,224( 1 ) :63-74.
  • 4Mukherji SK,Quisling RG,Kubilis PS,et al. Intracranial arteriovenous malformations: quantitative analysis of magnitude contrast MR angiography versus gradient-echo MR imaging versus conventional angiography [J].Radiology, 1995, 196(1): 187-193.
  • 5Hoch JR,Tullis MJ,Kenell YW,et al. Use of magnetic resonance angiography for the preoperative evaluation of patients with infrainguinal arterial occlusive diseases [J].J Vasc Surg, 1996,123 ( 1 ) :792-800.
  • 6Cortell ED,Kaufman JA,Geller SC,et al. MR angiography of tibial runoff vessels: imaging with the head coil compared with conventional arteriography [J]. AJR Am J Roentgenol, 1996,167 ( 1 ): 147-151.
  • 7Liu K,Lee DH,Rutt BK. Systematic assessment and evaluation of sliding interleaved kY (SLINKY) acquisition for 3D MRA [J]. J Magn Reson Imaging,1998,8(4):912-923.
  • 8Liu K,Tanttu J,Castren A,et al. Scanning time efficient slinky for non-contrast MRA at low field[J]. Magn Reson Imaging, 1999,17 (5): 689-698.
  • 9Morasch MD, Collins J, Pereles FS, et al. Lower extremity stepping-table magnetic resonance angiography with multilevel contrast timing and segmented contrast infusion [ J ]. J Vasc Surg, 2003,37 ( 1 ): 62-71.
  • 10Khilnani NM, Winchester PA,Prince MR,et al. Peripheral vascular disease :combined 3D bolus chase and dynamic 2D MR angiography compared with X-ray angiography for treatment planning[J]. Radiology,2002,224( 1 ) :63-74.

二级参考文献6

  • 1Vosshenrich R;Fischer U;Grable E.Initial experiences with the MR magnitude contrast angiography of the lower extremities,1993.
  • 2Unger EC;Schilling JD;Awad AN.MR angiography of the foot and ankle[J],1995(05).
  • 3Hoch JR;Tullis MJ;Kenell YW.Use of magnetic resonance angiography for the preoperative evaluation of patients with infrainguinal arterial occlusive diseases[J],1996.
  • 4Boos M;Schlegel E;Cramer BM.Magnitude contrast angiogrphy in peripheral arterial occlusive disease of the lower extremities,1995.
  • 5Quinn SF;Sheley RC;Semonsen KG.Aortic and lower extremity arterial disease:evaluation with MR angiography versus conventional angiography,1998.
  • 6Shetty AN;Shirkhoda A;Bis KG.3D breath-hold contrast-enhanced MRA:a preliminary experience in aorta and iliac vascular diseases[J],1998.