摘要  根据分宜发电有限公司首台国产 100 MW 循环流化床(CFB)锅炉两年来的运行实绩,对其技术特点、点火起动、额定负荷下热态运行、烟气污染物(SO2 和NOx)排放特性、运行优化调整和性能试验等以及存在的问题进行了介绍,可对国内CFB锅炉的设计和运行起到较好的参考作用。 Based on operational performance of the firstly homemade 100MW circulating fluidized bed (CFB) boiler at Fengyi PowerGeneration Company, Jiangxi Province, in recent two years the technical features, ignition for startingup, hotstate operation under rated load, and emission properties of flue gas pollutants (SO_2 and NO_x), as well as situation and problems occurred in aspeats of optimized adjustment and performance test etc. have been presented, giving certain reference value for design and operation of CFB boilers in China.
出处 《热力发电》 CAS 北大核心 2005年第2期30-35,共6页 Thermal Power Generation
关键词 CFB锅炉 燃烧 脱硫 国产100 MW CFB锅炉 CFB boiler combustion desulfuration homemade 100MW CFB boiler
  • 相关文献

参考文献5

  • 1张敏,蔡元丰.内江 410 t/h CFB 锅炉技术特点介绍[J].中国电力,1997,30(6):6-9. 被引量:10
  • 2蒋敏华 等.大型循环流化床锅炉技术[R]..西安热工研究院技术论文集[C].,1998..
  • 3孙献斌 王智微 等.100 MW CFB锅炉及相关系统设计研究[R].西安热工研究院,2001..
  • 4张敏.100 MW CFB锅炉点火系统设计研究[R].西安热工研究院,2001..
  • 5刘琦 等.江西分宜发电有限公司410 t/h循环流化床锅炉性能鉴定试验报告[R].电力工业热力发电设备及材料质量检验测试中心,2004..