摘要
以东方锅炉(集团)股份有限公司410t/h循环流化床(CFB)锅炉在河北热电技改工程应用为例,从测点配置、主保护设立及模拟量控制方面分析了循环流化床锅炉热工控制系统的特点及存在的问题。
Take Dongfang Boiler Works manufactured 410 t/h CFB boilers used in power cogeneration technical renovation project in Hebei Province as examples, this paper analyzes the features and problems of the instrument dispensation and main protection installation, and analog control systems of CFB boilers are analyzed.
出处
《河北电力技术》
2004年第B12期19-22,共4页
Hebei Electric Power
关键词
CFB锅炉
配置
特点
CFB boiler
configuration
feature