摘要
采用普通极谱仪与计算机联机技术,用卡尔曼滤波处理以KSCN为支持电解质的Cd^(2+)和Ni^(2+)混合溶液的示波极谱重叠波。实验表明,极谱可逆波具有较好的加和性,可采用计算极谱方法对多组分(尤其是难以分开的重叠波)进行同时测定。
The overlapping polarographic waves of Cd and Ni in 1.0 mol/L KSCN electrolyte can be resolved by using kalman filtering and a method for determing both elements simultaneously is developed. The method is simple and accurate. The average recoveries for Cd( Ⅱ)and Ni(Ⅱ )were 94. 50% and 99. 97% respectively.
出处
《岩矿测试》
CAS
CSCD
北大核心
1993年第1期46-49,共4页
Rock and Mineral Analysis
关键词
镉
镍
极谱法
卡尔曼波波
测定
cadmium and nickel determination,kalman filter,polarography