医院手术室净化空调系统设计中,根据不同级别手术室,确定送风量和组织气流,导入了污染度、局部强化送风、新风系统、定风量阀等措施,取得了较好效果。
In hospital an operation room air tumbler air conditioner system design,design according to alike distinction an operation room,confirm amount of blast and air current distribution, lead degree of pollution, local consolidateblast,freshwind system, vav valveand so on measure acquire preferably effect.