可变冷热流换热网络的夹点和最小外界供热调优 被引量:2

OPTIMIZATION OF MINIMUM UTILITY USAGE OF HEAT EXCHANGER NETWORK WITH VARIABLE HOT ANDLOR COLD STREAMS AND PINCH
下载PDF
导出
摘要 本文提出可变冷热流换热网络最小外界供热的调优启发式规则。给出了四种情况下的算法。对于普遍适用的可变冷热流最小外界供热问题,提出用可变容差法结合调优求解的算法。以常减压装置为例,调优后可使最小外界供热降为82.9%。表明多夹点常比单尖点可节省更多能量。 This paper proposes the heuristic rules for the optimization of minimum utility usage with variable hot and/or cold streams. Algorithms for four cases are given. Flexible tolerance method associated with optimization is suggested to be used for the general case. An example shows that this method can decrease minimum utility usage down to 82.9% and multi-pinches usually make lower minimum utility than single-pinch does.
作者 徐亦方
机构地区 石油大学
出处 《石油大学学报(自然科学版)》 CSCD 1989年第5期85-91,共7页 Journal of the University of Petroleum,China(Edition of Natural Science)
关键词 换热网络 夹点 最小公用工程 调优 Heat exchanger network Pinch Optimization Minimumutillty usage Threshold point