摘要
1992年1月马头发电厂4号机6号轴承发生异常振动,高负荷时轴向振动最大曾超过300μm。经过一系列试验分析,确认引起振动的原因是发电机转子出现匝间短路。经处理后恢复正常。本文介绍了这次诊断工作,并绘出了主要试验数据。
The NO. 6 beating of the NO. 4 turbine generator unit of Matou Power Plant experienced an abnormal vibration inJannuary 1992, the maximum axial level of which at higher load once exceeded 300nm.It was confirmed through a seriesof testing and analysis that the vibration was caued by the interturn short circuit of generator rotor. Presented in this paperare some of the main testing data and diagnosing work.
出处
《热力发电》
CAS
北大核心
1994年第2期49-53,共5页
Thermal Power Generation