摘要
叙述了25000kVA电炉变压器损坏后在修复方面所做的工作。变压器修复后采取热油喷雾真空干燥,经测试表明,变压器现场大修是成功的,为大型铁合金电炉变压器检修技术开创了一条新路。
The renovation work done for a demaged furnace transformer is described. After the transformer having been repaired, it was dried by hot oil spraying. Test showed that the on-site repair was successful. This initiated a new approach to the renovating technique of ferroalloy furnace transformer.
出处
《铁合金》
北大核心
1989年第6期18-22,共5页
Ferro-alloys