期刊文献+

水中铝的络合吸附极谱测定法 被引量:5

Determination of Aluminium(Ⅲ) in Water by Complex Adsorptive Polarogaphy
下载PDF
导出
摘要 目的建立水样中微量铝的极谱分析方法。方法在HOAc-NH4OH缓冲液-铍试剂Ⅲ-乙二胺四乙酸(EDTA)体系中,采用极谱法测定水样中的铝,并探讨了最佳实验条件。结果在pH=5.8的HOAc-NH4OH缓冲液中,铝-铍试剂Ⅲ络合物于-0.54V产生1个灵敏的络合吸附极谱波。该方法的线性范围为0.005~0.300μg/ml;检出限为0.003μg/ml。相对标准偏差为5.4%~9.1%,回收率为92.7%~108.0%。结论该方法灵敏、准确,有较高的选择性,适用于水中铝的测定。 Objective To set up a method for determination of the trace amounts of aluminium(Ⅲ) in water samples. Methods Second derivative polarogaphy was used. Results In a solution of acetate buffer(HOAc-NH4OH, pH=5.8), Al(Ⅲ)reacted with Berllon Ⅲ to form a complex and a sensitive polarogaphic adsorptive wave appeared at -0.54 V(vs.SCE). By using the 2nd derivative polarogaphy measyrement, the wave height had a linear relationship with the concentration of Al(Ⅲ)in the range of 0.005-0.300 μg/ml. The limit of detection was 3.0 ng/ml. RSDs were 5.4%-9.1%. Recovery rates were 92.7%-108.0%. Conclusion The present method is sensitive, accurate with high selectivity and can be applied to the determination of the trace amounts of Aluminium(Ⅲ) in water sample with satisfactory results.
作者 徐赟
出处 《环境与健康杂志》 CAS CSCD 北大核心 2005年第2期142-143,共2页 Journal of Environment and Health
关键词 电化学 铍试剂Ⅲ Water Aluminium Electrochemistry Berllon (Ⅲ)
  • 相关文献

参考文献6

二级参考文献16

  • 1王慧琴,杨志斌.2,4-二羟苯甲醛异烟酰腙的合成及其与铝的荧光反应[J].分析化学,1996,24(5):587-590. 被引量:17
  • 2董增华,张立辉,陈守建.7-碘-8-羟基喹啉-5-磺酸荧光分光光度法测定水中铝[J].环境监测管理与技术,1996,8(1):31-34. 被引量:5
  • 3王夔.生命科学中的微量元素[M].北京:中国计量出版社,1991..
  • 4江亚芳.肾功能衰竭与铝积蓄[J].临床内科杂志,1986,6(2):639-639.
  • 5张锡安,分析化学,1993年,21卷,125页
  • 6李平,理化检验.化学分册,1991年,27卷,90页
  • 7邓水平,分析化学,1988年,16卷,892页
  • 8水质分析大全编写组.水质分析大全.第1版.重庆:科学技术出版社重庆分社,1989:233
  • 9钱文珍 黄玉芳 张国荣等.钢中微量酸溶铝的测定[J].理化检验:化学分册,1985,2(21):28-28.
  • 10王华凯 林菊英.铬天青S—乳化剂OP光度法测定水中铝[J].理化检验:化学分册,1985,2(21):30-30.