Investigation on absorptive material position in small rooms with finite element method

Investigation on absorptive material position in small rooms with finite element method
原文传递
导出
摘要 Four small rooms have been modeled by finite element method, and the proper position for the absorptive material is found through the investigation on the sound field below 100 Hz. It is shown that the modes' maximum pressure occur in all the corners in the rectangular room, but in the non-rectangular rooms, the pressure distribution is complex in some corners where some modes' minimum pressure may even occur. By comparing the average SPL curves which is the absorptive material at different positions, it is seen that the proper absorptive material position contributes greatly to the flatness of the curves , which is also proved by experiments in a reverberation room. So the absorptive material should not be placed in the corners where the mode's minimum pressure gathered but where the modes' maximum pressure gathered. In order to place absorptive material effectively in non-rectangular rooms, the conclusion drawn by modal superposition method in rectangular rooms shouldn't be applied directly, and it is favorable to analyze the non-rectangular rooms' sound field by the finite element method. Four small rooms have been modeled by finite element method, and the proper position for the absorptive material is found through the investigation on the sound field below 100 Hz. It is shown that the modes' maximum pressure occur in all the corners in the rectangular room, but in the non-rectangular rooms, the pressure distribution is complex in some corners where some modes' minimum pressure may even occur. By comparing the average SPL curves which is the absorptive material at different positions, it is seen that the proper absorptive material position contributes greatly to the flatness of the curves , which is also proved by experiments in a reverberation room. So the absorptive material should not be placed in the corners where the mode's minimum pressure gathered but where the modes' maximum pressure gathered. In order to place absorptive material effectively in non-rectangular rooms, the conclusion drawn by modal superposition method in rectangular rooms shouldn't be applied directly, and it is favorable to analyze the non-rectangular rooms' sound field by the finite element method.
机构地区 InstituteofAcoustics
出处 《Chinese Journal of Acoustics》 2005年第2期186-192,共7页 声学学报(英文版)
基金 ThisworkwassupportedbytheNationalNaturalScienceFoundationofChina(10474046).
  • 相关文献

参考文献3

二级参考文献13

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部