期刊文献+

EFFECTS OF COPPER ION IMPLANTATION ON ANTIBACTERIAL ACTIVITY OF AISI420 STAINLESS STEEL 被引量:1

EFFECTS OF COPPER ION IMPLANTATION ON ANTIBACTERIAL ACTIVITY OF AISI420 STAINLESS STEEL
下载PDF
导出
摘要 Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2.0×1017ions·cm-2. The saturation dose of Cu implantation in AISI420 SS and Cu surface concentration were calculated at the energy of 100keV. The effect of dose on the antibacterial activity was analyzed. Results of antibacterial test show that the saturation dose is the optimum implantation dose for best antibacterial activity, which is above 99% against both Escherichia coli and Staphylococcus aureus. Novel phases such as Fe4Cu3 and Cu9.9Fe0.1 were found in the implanted layer by glancing angle X-ray diffraction (GXRD). The antibacterial activity of AISI420 SS attributes to Cu-contained phase. Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2.0×1017ions·cm-2. The saturation dose of Cu implantation in AISI420 SS and Cu surface concentration were calculated at the energy of 100keV. The effect of dose on the antibacterial activity was analyzed. Results of antibacterial test show that the saturation dose is the optimum implantation dose for best antibacterial activity, which is above 99% against both Escherichia coli and Staphylococcus aureus. Novel phases such as Fe4Cu3 and Cu9.9Fe0.1 were found in the implanted layer by glancing angle X-ray diffraction (GXRD). The antibacterial activity of AISI420 SS attributes to Cu-contained phase.
出处 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2005年第2期153-158,共6页 金属学报(英文版)
基金 This work was supported by the National Natural Science Foundation of China(No.50101009)
关键词 antibacterial stainless steel copper ion implantation saturation dose Cu-contained phase antibacterial stainless steel, copper ion implantation, saturation dose, Cu-contained phase
  • 相关文献

参考文献14

  • 1S. Nakamura, N. Ookubo. K. Miyakusu, M. Hasegawa and Y. Munesue, Nisshin Steel Technical Reports 76(1997) 48.
  • 2F. Halitim, N. lkhlef, L. Boudoukha and G. Fantozzi, Thin Solid Films 300 (1997) 197.
  • 3P. Sioshansi, Nucl. Instrum. Meth. B 37/38 (1989) 667.
  • 4V. Lavemtiev, V. Adeev, A. Kotko and A. Tolopa, Surf. Coat. Technol. 106 (1998) 145.
  • 5S. picard, J.B. Memet and R. Sabot, Mat. Sci. Eng. .A303 (2001) 163.
  • 6C. Cordier-Robert, L. Bourdeau and T. Magnin, Mat. Lett. 20 (1994) 113.
  • 7F.J. Perez, M.P. Hierro and C. Gomez, Su.rf Coat. Technol. 155 (2002) 250.
  • 8W.Y. Han, Pathogenic Bacteria Testing Technology (Jilin Science and Technology Press, Jilin, 1992) p.79 (in Chinese).
  • 9T. Yokota, M. Tochibara and M. Ohm, Kawasaki Steel Technical Reports 46 (2002) 37.
  • 10J.F. Ziegler, Ion Implantation Science and Technology (Academic Press Inc, New York, 1984) p.51.

同被引文献8

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部