期刊文献+

微电解-UASB-MBR法联用处理抗生素废水的试验研究 被引量:3

Treatment of antibiotic wastewater by microelectrolysis-UASB-MBR
下载PDF
导出
摘要 采用“铁炭微电解-厌氧-好氧”工艺处理抗生素制药废水,试验证明:在铁炭体积比为1:1,pH值为4~5、厌氧段HRT大于5h的条件下,当抗生素废水进水CODcr在2 0 0 0~80 0 0mg·L-1时,总COD去除率可达85 %以上,出水达到GB8978- 96二级排放标准。 Antibiotic wastewater was treated by microelectrolysis-UASB-MBR.The results showed that as to the volume ratio of iron and charcoal is 1:1,pH value is 4~5,the hydraulic retention time(HRT) of the anaerobic reactor is longer than five hours,the inlet wastewater with CODcr is between 2000~8000mg·L -1 ,the removal efficiency of CODcr is higher than 85%, and the outlet water treated by this process is quiet enough meet the wastewater discharge standard of GB8978-96.
出处 《化学工程师》 CAS 2005年第5期1-3,26,共4页 Chemical Engineer
基金 2 0 0 3年上海市教委自然科学项目 (0 3AK60 )
关键词 微电解 厌氧 好氧 抗生素废水 microelectrolysis UASB MBR antibiotic wastewater
  • 相关文献

参考文献6

二级参考文献70

共引文献208

同被引文献40

引证文献3

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部