摘要 本文分析制冷剂冷凝温度、循环冷却水温和流量对制冷量的影响,并根据华南沿海地区夏季气候湿热,冷却塔负荷过大而冷却水温往往达不到额定工况的特点,结合冷凝热回收和喷泉冷却系统的工程实例,探讨降低冷却塔负荷及冷却水温的方法。 In this paper, the effects of the refrigerant condensation temperature, the temperature and flowing rate of the circulating cooling water on the cooling capacity are analyzed. The temperature of cooling water in cooling tower usually can not meet the requirement of working system in the foreland of south China since it is hot and humid weather. In order to improve the cooling system, we investigated the ways to lower the load and decrease the cooling water temperature for the cooling tower by using the condensation heat and fountain cooling system based on some engineering examples.
作者 李迎建
机构地区 深圳大学理学院
出处 《节能技术》 CAS 2005年第3期222-225,231,共5页 Energy Conservation Technology
关键词 冷却水参数 冷凝热 气候环境 冷却塔负荷 cooling water parameter condensation hot climate environment cooling tower load
  • 相关文献

参考文献4

  • 1Dossat,Roy J.Principles of refrigeration 2nd edition 1978.
  • 2汤学忠.动力工程师手册[M].北京:机械工业出版社,1999.25.
  • 3深圳市气象局.2003年深圳市天气气候公报[R].深圳,2004,3..
  • 4李惟毅,韦雪松,郑宗和,杨立新.集中空调冷凝热回收的应用[J].暖通空调,2004,34(7):105-107. 被引量:11

二级参考文献7

  • 1周邦宁.中央空调设备选型手册.北京:中国建筑工业出版社,1999
  • 2汤蕙芬,范季贤.城市供热手册.天津:天津科学技术出版社,1992
  • 3杨崇麟.板式换热器工程设计手册.北京:机械工业出版社,1994
  • 4赵国杰.工程经济与项目评价.天津:天津大学出版社,2000
  • 5Alex H W Lee, Jerold W Jones. Thermal performance of a residential desuperheater water heater system.Energy Conversion and Management, 1996(4)
  • 6Kaushik S C. Feasibility and design studies for heat recovery from a refrigeration system with a canopus heat exchanger. Heat Recovery Systems and CHP,1995(7)
  • 7张万路.压缩蒸发式中央空调系统余热利用的前景[J].应用能源技术,2002(5):21-23. 被引量:5