摘要 目的 探讨使用肝素钠抗凝剂、促凝剂、分离胶等添加剂处理的标本是否适合锂盐(Li+ )浓度的监测。方法 选择临床服用碳酸锂治疗达稳态的住院患者,使用真空采血系统分别采集普通管血液标本和分别含有肝素钠抗凝剂、促凝剂、分离胶等添加剂的标本,在IMS 972电解质分析仪上测定Li+浓度,比较结果的差异。结果 (1)不同方式处理的标本间Li+浓度差异有显著性(P<0. 001),其中普通血清、肝素钠抗凝血浆、促凝剂处理的血清之间Li+浓度差异均无显著性(P>0. 05),分离胶处理的标本与普通血清、促凝剂和肝素钠处理的标本之间Li+浓度差异均有显著性(P<0. 001); (2)肝素钠抗凝剂和促凝剂处理的标本与普通血清Li+浓度之间呈高度线性相关(r=0. 988~0. 993, P<0. 001),分离胶处理的标本与普通血清、肝素钠抗凝剂、促凝剂处理标本的Li+浓度线性相关均无显著性(r=0. 203~0. 288,P>0. 05); (3)肝素钠抗凝剂、促凝剂、分离胶等添加剂处理标本和普通血液标本,不分离血凝块室温放置8h,Li+浓度较放置前增高(P<0. 05~0. 001)。结论 促凝剂和肝素处理标本适合用于锂盐的快速测定,而分离胶处理的标本不适合用于离子选择电极法测定Li+浓度,也不适于储存和标本运输;使用肝素钠抗凝剂和促凝剂处理的标本。 Objective To explore that blood sample treated with additive reagents is suitable or not for the measurement of lithium salt(Li^+) concentration. Methods Blood samples from inpatients treated with lithium carbonic acid were collected using common vacuum tube, or containing heparin sodium anti-coagulating reagent, promoting coagulating reagent, gel separator and determined for serum Li^+ concentration by IMS-972 electrolyte analyzer. Results (1) Li^+ concentrations of common serum, heparin anti-coagulated plasma and serum dealt with promoting coagulating reagent showed no difference (P>0.05). There were significant difference between sample dealt with gel separator and other samples(P<0.001); (2) Li^+ concentrations of samples dealt with anti-coagulating reagent, promoting coagulating reagent and common serum showed high linearity correlation (r=0.988-0.993, P<0.001). Li^+ concentrations of sample dealt with gel separator showed no obvious difference in linearity correlation with other samples(r=(0.203)-(0.288),P>0.05); (3) After placed 8 hours in room temperature, Li^+ concentrations of all samples increased obviously (P<0.05-0.001). Conclusions The samples dealt with promoting coagulating reagent and heparin sodium anti-coagulatnt are suitable to be used for the measurement of lithium salt while the sample dealt with gel separator is not suitable for the method of ion selection electrode.
出处 《检验医学》 CAS 北大核心 2005年第3期230-232,共3页 Laboratory Medicine
基金 河南省自然科学基金资助项目(0124170744)
  • 相关文献

参考文献8

  • 1Soares JC,Gershon S.The psychopharmacologic of lithium ion:origins and trajectory[J].J Clin Psychiatry,2000,61:16.22.
  • 2Bowdern CL. Efficacy of lithium in mania and maintenance therapy of bipolar disorder[J]. J Clin Psychiatry, 2000,61:35-40.
  • 3沈其杰.锂治疗心境障碍的50年回顾[J].中华精神科杂志,2004,37(1):1-3. 被引量:19
  • 4王焕林 高柏良 等.锂盐治疗对心电图及血清电解质的影响[J].中华神经精神科杂志,1987,20(1):56-56.
  • 5张明园 王克勋 等.碳酸锂治疗剂量的预测[J].中华神经精神科杂志,1984,17(4):239-239.
  • 6郭新胜,王文凤,张晨光.自制锂质控血清在电解质分析仪上的应用[J].上海医学检验杂志,1999,14(4):244-245. 被引量:7
  • 7Murthy J, George M, Rehak N. Short-term of serum at room temperature in gel separator tubes: effect on common chemistry tests determined with Hitachi 917 [J].Clin Chem, 2000,46: A37.
  • 8郭新胜,李玉凤,吴效梅,苏莉,王来海,张长军.标本因素对离子选择电极法测定血锂浓度的影响[J].检验医学,2004,19(1):62-64. 被引量:14

二级参考文献10

共引文献36

同被引文献89

引证文献11

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部